19
Boiler installation sequence 4
Instructions for installation and servicing ecoMAX
19
4.14.4 Connection details for programmable thermostats
Fig. 4.14
L
N
2
3
4
L
N
3
4
1
ACL Drayton
Lyfestyle PT271, PT371
ACL Drayton
Digistat 2, 3, 4
ACL Drayton
Digistat RF - SCR Receiver
Danfoss Randall
TP4, TP5
Danfoss Randall
TP7000-RF with receiver RX1
Danfoss Randall
TP7000
Grässlin Towerchron
RTC7
Honeywell
CM61, CM67, CM31, CM37
Horstmann
Centaurstat 1, 7
Landis & Staefa
REV 11, REV 15, REV 22
1
2
3
4
3
Sunvic
TLX 6501
Sunvic
TLX RFP, TLX RFD
Vaillant
VRT 230, 220
N
1
3
N
3
2
L
L
4
3
2
4
3
1
L
N
2
3
4
L
N
3
4
1
2
3
4
1
3
5
6
4
1
2
3
4
3
A
B
3
4
C
1
2
4
3
4
3
L
L1
3
4
Smiths Timeguard
ProgramaSTAT PRT11, PRT17
L
N
4
L
N
3
3
4
1
2
3
4
3
L
N
2
3
4
L
N
3
4
1
3
4
3
4
5
5
7
4.15 Controls
4.15.1 External electrical controls
The boiler terminals 3, 4 and 5 are for connecting exter-
nal electrical controls such as a programmer, room ther-
mostat, etc. Terminals 3 and 4 are linked together when
the boiler is supplied. If external controls are used, this
link must be removed, and the controls connected
across terminals 3 and 4. Terminal 5 is an additional
neutral connection for external controls.
4.15.2 Connection of external electrical controls
4.15.3 Connection details using an external wiring
centre
The boiler should be connected to the system controls
using an external wiring centre. Fig. 4.15 shows connec-
tion details for a system utilising a 3 port mid position
motorised valve, figure 4.16, 4.17 shows the connection
details for a system utilising two 2 port motorised valves
(Important: the arrowed numbers indicate connection
into the relevant terminal of the external wiring centre).
80020014605_00GB_032006 22.02.2006 21:35 Uhr Seite 19