background image

16

Split Type User Manual

Fresh Air function (optional):
-  The outdoor air can enter indoors through the fresh 

air tube, keeping the indoor air fresh.

-  To change from health function to fresh air function, 

press the FRESH button (fresh air indicator will appear 
on the display).

-  To cancel the health function press the FRESH button 

again.

  Note!

The HEALTH indicator will light when the indoor 
unit fan does not function even if the anion 
generator is not operating.

7.7.2  Health Airflow Operation (HEALTH FLOW)

The direction of the ionised airflow can be set in vertical 
and horizontal directions.

Fig. 7.19  HEALTH FLOW function selection.

Legend

1  HEALTH FLOW button

In order to activate:
•  Press the HEALTH FLOW button to direct horizontally.
  The horizontal flow indicator will appear on the 

display.

  The unit's bottom inlet and outlet grates will close and 

the airflow will circulate horizontally from the top inlet 
and outlet grates. 

•  Press the HEALTH FLOW button again to direct 

vertically.

  The vertical flow indicator will appear on the display.
  The unit's top inlet and outlet grates will close and the 

airflow will circulate vertically from the bottom inlet 
and outlet grates. 

•  Press the HEALTH FLOW button again to cancel the 

health airflow function.

  Both the inlet and outlet grates will remain open 

operating in the mode in which the unit was 
configured before activating the health airflow 
function.

  Note!

After configuring the health airflow function, the 
inlet and outlet grates will be fixed.
Select the adequate fan direction according to 
the real conditions.

  Note!

In cooling and dehumidifying mode, prolonged 
use of the unit under conditions of considerable 
air humidity can cause drops of water to fall on 
the outlet grate.

  Note!

In HEAT mode it is better to select the vertical 
flow direction
In COOL mode it is better to select the horizontal 
flow direction.

7 Operating Instructions

Summary of Contents for climaVAIR V 7-025 NW

Page 1: ...V 7 025 NW V 7 035 NW V 7 050 M2N V 7 060 M2N V 7 075 M3N V 7 085 M3N climaVAIR DE EN ES HR IT NL ...

Page 2: ...For the user User Manual Air Conditioner climaVAIR Split Type EN V 7 025 NW V 7 035 NW V 7 050 M2N V 7 060 M2N V 7 075 M3N V 7 085 M3N ...

Page 3: ...ical Airflow 14 7 6 2 Horizontal Airflow 15 7 7 Special Function Selection 15 7 7 1 Health Anion Operation HEALTH 15 7 7 2 Health Airflow Operation HEALTH FLOW 16 7 7 3 SLEEP Function 17 7 7 4 TIMER ON OFF Function CONNECTION DISCONNECTION USING TIMER 18 7 7 5 POWER SOFT Function 19 7 8 Emergency Operation and Operation Test 20 7 8 1 Emergency Operation 20 7 8 2 Operation Test 20 7 8 3 Cancellatio...

Page 4: ... and in the user manual Vaillant does not accept any responsability for damages that may arise from non observation of the following instructions Note The Installation of the unit has to be done by qualified people Do not install it yourself All electrical repairs should be also carried out by qualified electricians Note Please read this User Manual carefully before using the air conditioning Note...

Page 5: ...th the standard in force with regard to obtaining the CE Marking 5 Description of the Unit This unit is comprised of the following elements Outdoor unit Indoor unit Remote controller and holder Connections and channels Accessories Figure 5 1 shows the unit components Fig 5 1 Unit components Legend 1 Indoor Unit 2 Outdoor unit 3 Remote controller and holder 4 Connections and channels 5 Condensed wa...

Page 6: ...ting strange odours and maintaining a fresh atmosphere This filter s exposure to sunlight regenerates its anti odour capacity Anti bacterial filter Filter with an anti allergic and anti bacterial effect which keeps the atmosphere clean and healthy Anti dust filter Anti dust filter Remote controller Remote controller using infrareds Hot start function Start and stop with hot battery which avoids th...

Page 7: ...there is anything still showing on display just press the reset button Remove the batteries in case the air conditioning is out of use for a long period If there is anything still showing on display just press the reset button Warning Danger of the enviromental contamination by not disposing of the batteries properly When replacing the remote controller batteries leavethe old batteries in suitable...

Page 8: ...rface If the refrigerant spurts out and gets into your eyes it may result in serious eye injuries Do not interrupt the operation of the air conditioning unit by pulling the cord Danger of injury and physical damage Danger of fire and explosion Damaged air conditioners should not be put into operation In case of doubt consult your supplier The air conditioner must be properly grounded in accordance...

Page 9: ...WN button AIRFLOW DIRECTION UP DOWN 15 SWING LEFT RIGHT button AIRFLOW DIRECTION LEFT RIGHT 16 FRESH button 17 SET button SETTING 18 POWER SOFT button 19 RESET button 7 2 2 Display Indicators Fig 7 2 Overview of the indicators Legend 1 TIMER ON indicator 2 FAN SPEED indicator 3 LOCK indicator 4 SWING UP DOWN indicator AIRFLOW DIRECTION UP DOWN 5 SLEEP indicator NIGHTTIME FUNCTION 6 HEALTH indicato...

Page 10: ...nnection Disconnection of the Unit In order to connect the unit Press the ON button on the indoor unit or on the remote controller the unit will start to operate The liquid crystal display LCD will show the latest operating status of the unit except the HEALTH SLEEP POWER SOFT and TIMER ON OFF functions In order to disconnect the unit Press the OFF button on the indoor unit or on the remote contro...

Page 11: ...Press the TEMP buttons to select the temperature setting When pressing the TEMP buttons the temperature configuration will increase or decrease by 1ºC When keeping the TEMP buttons pressed the temperature configuration will increase or decrease quickly Press the FAN button to select the fan speed Each time the FAN button is pressed the fan speed will be modified as shown in Figure 7 7 Fig 7 7 Fan ...

Page 12: ...e or decrease by 1ºC When keeping the TEMP buttons pressed the temperature configuration will increase or decrease quickly Press the FAN button to select the fan speed Each time the FAN button is pressed the fan speed will be modified as shown in Figure 7 10 Fig 7 10 Fan speed The operation in cooling mode is started when the ambient temperature is greater than the configured one In dehumidifying ...

Page 13: ...ion mode Legend 1 MODE button 2 FAN mode indicator 3 FAN button In order to activate the fan mode FAN With the unit connected see section 7 4 Press the MODE button The different operation modes are displayed AUTO COOL DRY FAN HEAT Fig 7 13 Operation modes Select the fan operation mode FAN Press the FAN button to select the fan speed Each time the FAN button is pressed the fan speed will be modifie...

Page 14: ...elect the heating operation mode HEAT Press the TEMP buttons to select the temperature setting When pressing the TEMP buttons the temperature configuration will increase or decrease by 1ºC When keeping the TEMP buttons pressed the configured temperature will increase or decrease quickly Press the FAN button to select the fan speed Each time the FAN button is pressed the fan speed will be modified ...

Page 15: ...is recommendable to direct the grates vertically Note In cooling mode it is recommendable to direct the grates horizontally 7 6 1 Vertical Airflow Press the SWING UP DOWN button to direct the airflow upwards or downwards The vertical slat will be directed in accordance with the positions allowed for each operation mode On the remote controller or the control panel of the indoor unit the different ...

Page 16: ...th Anion Operation HEALTH The anion generator of the air conditioning unit has the following functions To generate anions to neutralise the quantity of cations and anions in the air To kill bacteria To accelerate the sedimentation of dust in the room to clean the room air UV light degerming function UV light emitted by the UV light device of the indoor unit catalitically activates the nano TiO2 on...

Page 17: ... and the airflow will circulate horizontally from the top inlet and outlet grates Press the HEALTH FLOW button again to direct vertically The vertical flow indicator will appear on the display The unit s top inlet and outlet grates will close and the airflow will circulate vertically from the bottom inlet and outlet grates Press the HEALTH FLOW button again to cancel the health airflow function Bo...

Page 18: ...d T1 Configured temperature to Start of the SLEEP function In HEAT mode The ambient temperature decreases 2ºC in relation to the configured one to ensure that the temperature does not rise excessively during the sleep hours During the first operating hour of the SLEEP function the ambient temperature will drop 2ºC below the configured temperature Once an hour has elapsed the temperature will drop ...

Page 19: ...he desired time When pressing the HOUR buttons the time configuration will increase or decrease by 1 minute If the HOUR buttons are kept pressed the time will increase or decrease rapidly The time can be set within an interval of 24 hours Press the SET button to confirm the time The ON or OFF indicators will stop flashing Time display the unit starts to operate or stops after x hours x minutes In ...

Page 20: ...atically in HI high for 15 minutes in order to put the configuration back to its original state To cancel the POWER function Press the POWER SOFT button twice The indicator will disappear To activate the SOFT function Press the POWER SOFT button Each time you press the button you will modify the display configuration see Figure 7 26 Stop the display in SOFT function In SOFT function the fan speed ...

Page 21: ...y operation operation test switch Legend 1 Emergency operation operation test switch Note When in emergency operation the dehumidifying mode is not available 7 8 2 Operation Test Only use this function to carry out operation tests when the temperature is less than 16ºC In order to activate Lift the front lid of the indoor unit Keep the emergency operation operation test switch pressed for more tha...

Page 22: ...om is heated In addition to the surfaces which delimit this area i e the walls doors windows ceiling and floor the adjacent rooms are also heated uncontrollably thermal energy is unintentionally lost It is therefore impossible to adequately heat the room and an unpleasant feeling of cold is felt the same occurs when leaving open doors which separate heated areas and unheated areas in a limited way...

Page 23: ...ture in cooling mode or excessively low in heating mode Set the temperature properly Obstacle in front of the air inlet or outlet Remove the obstacle to allow the air to circulate properly The ambient temperature has not reached the designated level Wait for a few moments Dirty or blocked air filter Clean the air filter the air filter should be cleaned every 15 days Is there any direct sunlight th...

Page 24: ...til it is released from the stopper and remove the filter downwards Clean the filter removing the dust or the dirt using a vacuum cleaner or cleaning them with cold water Ensure that the filters are dried completely dry in the shade before putting them back into the unit Attach the filter correctly and make sure it is completely fixed behind the stopper If the right and left filters are not proper...

Page 25: ...ary precautions are taken In order to do so follow the steps described in the installation manual in reverse order and use the necessary tools and protection resources Ensure that the disassembly is carried out by qualified technically competent individuals Warning Danger of environmental contamination when disposing of the unit To avoid this follow the instructions described in this section Warni...

Page 26: ......

Reviews: