7.8
Emergency Operation and Operation Test
7.8.1 Emergency Operation
Only use this function when the remote controller is
broken or has been mislaid.
In emergency operation the unit automatically selects
the operation modes, Cooling or Heating depending on
the ambient temperature, see Table 7.3.
Temperature Operation Mode
Desired
Temp.
Timer Mode
Airflow
>
23ºC
Cooling
26ºC
No
Auto
<
23ºC
Heating
23ºC
No
Auto
Tab. 7.3 Emergency Operation.
In order to activate:
• Press the emergency operation/operation test switch.
A beeping noise is heard which indicates that the
function has been put into operation.
Fig 7.30 Emergency operation/operation test switch.
Legend
1
Emergency operation/operation test switch
Note!
When in emergency operation the dehumidifying
mode is not available.
7.8.2 Operation Test
Only use this function to carry out operation tests when
the temperature is less than 16ºC.
In order to activate:
• Lift the front lid of the indoor unit.
• Keep the emergency operation/operation test switch
pressed for more than five seconds.
A beep is heard twice which indicates the start of the
function in cooling mode with the HI (high) airflow
speed.
• Release the switch.
After 30 minutes the function test will end
automatically.
7.8.3 Cancellation of Emergency Operation/
Emergency Test
• Press the emergency operation/operation test switch
once again or use the remote controller.
The beeping stops.
The unit returns to normal operating mode.