4 Operation
8
Operating instructions atmoTEC exclusive, atmoTEC plus 0020214277_01
Information on the data
plate
Meaning
Type (e.g. B
11
)
Gas-fired boiler types
2E, G20
–
20 mbar (2.0 kPa)
Gas group and gas connection
pressure as set at the factory
ww/yyyy (e.g. 11/2014)
Date of manufacture:
Week/year
PMW (e.g. 10 bar (1 MPa))
Permissible total excess pres-
sure during domestic hot wa-
ter generation
PMS (e.g. 3 bar (0.3 MPa))
Permissible total excess pres-
sure in heating mode
P
Nominal heat output range
T
max.
(e.g. 85 °C)
Max. flow temperature
Q
Heat input range
D
Nominal domestic hot water
draw-off rate
Heating mode
Domestic hot water generation
Barcode with serial number,
The 7th to 16th digits of the
serial number form the article
number
3.3
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
4
Operation
4.1
Opening the isolators
1.
Ask the competent person who installed the product to
explain to you where these isolators are located and
how to handle them.
2.
Open the gas stopcock installed on-site.
3.
Open the gas stopcock on the product.
4.
Open the service valves in the heating installation's flow
and return.
Applicability:
Product with integrated domestic hot water generation
OR Product with connected domestic hot water cylinder
▶
Open the cold-water isolation valve.
4.2
Checking the system pressure on the
manometer
E
bar
1
▶
Before starting up the unit, check the installation's filling
pressure on the manometer
(1)
. To ensure that the heat-
ing installation works correctly, a filling pressure between
1.0 and 2.0 bar should be displayed when the installation
is cold (the indicator on the manometer is then located in
the light-grey area). If the filling pressure is lower than 0.8
bar (the indicator on the manometer is then in the dark-
grey area), it must be filled with water before start-up (
→
section "Filling the heating installation").
Note
If the heating installation extends over several
storeys, a higher filling pressure may be re-
quired. Ask your competent person for details.
4.3
Starting up the product
▶
Only start up the product once the casing has been com-
pletely closed.
4.4
Switching on the product
E
bar
1
1.
Use the main switch
(1)
to switch on the product.
◁
1
: "ON"
◁
When the main switch is in position
1
, the product is
switched on and the standard display for the Digital
Information and Analysis System is shown in the
display .
2.
Set up your product according to your needs.