background image

2 Notes on the documentation

6

Operating instructions atmoTEC exclusive, atmoTEC plus 0020214277_01

2

Notes on the documentation

2.1

Observing other applicable documents

You must observe all operating instructions enclosed with
the system components.

2.2

Storing documents

Keep this manual and all other applicable documents
safe for future use.

2.3

Validity of the instructions

These instructions apply only to:

Product article number

VC DE 104/4-7 A-P

0010018739

VC DE 104/4-7 A-L

0010018740

VC DE 104/4-7 A-H

0010018741

VCC 194/4-5 120 (E-DE), surface-
mounted

0010024478

VCC 194/4-5 120 (E-DE), concealed

0010024480

VCC 194/4-5 120 (LL-DE), surface-
mounted

0010024479

VCC 194/4-5 120 (LL-DE), concealed

0010024481

VCW DE 194/4-5 A-L

0010017844

VCW DE 194/4-5 A-H

0010017845

VCW DE 204/4-7 A-P

0010018745

VCW DE 204/4-7 A-L

0010018746

VCW DE 204/4-7 A-H

0010018747

VCW DE 244/4-5 A-L

0010017846

VCW DE 244/4-5 A-H

0010017847

VCW DE 254/4-7 A-P

0010018742

VCW DE 254/4-7 A-L

0010018743

VCW DE 254/4-7 A-H

0010018744

Applicability:

VCC 194/4-5 120 (E-DE), surface-mounted, VCC 194/4-5

120 (E-DE), concealed, VCC 194/4-5 120 (LL-DE), surface-mounted, VCC
194/4-5 120 (LL-DE), concealed

These instructions are only valid in conjunction with the in-
structions for:

VIH R 120/6 B

Cylinder retrofitting set

VRT 350

Piping set

Surface-mounted piping set for 120 l

Concealed piping set for 120 l

3

Product description

3.1

Overview of the control elements

E

bar

3

1

2

4

5

6

7

8

9

10

1

Display

2

i button

3

Control (accessory)

4

Manometer

5

Main switch

6

+ button

7

- button

8

Reset button

9

Heating flow temperat-
ure rotary knob

10

Domestic hot water
rotary knob

The display shows the current heating flow temperature, the
system pressure of the heating installation, the operating
mode or certain additional information.

The

i

button is used to call up status information.

The control, which is available as an accessory, automatic-
ally controls the flow temperature depending on the outdoor
temperature.

The manometer is used to mechanically display the current
filling pressure of the heating installation.

The main switch is used to switch the product on and off.

The

+

button is used to switch on the chimney sweep func-

tion.

The

button is used to switch on the chimney sweep func-

tion and to display the filling pressure of the heating installa-
tion.

The

Reset

button is used to reset the product in the case of

certain faults.

The heating flow temperature rotary knob is used to set the
heating flow temperature if no control is connected. If a con-
trol is connected, the heating flow temperature rotary knob
should be turned clockwise as far as it will go.

VC

/

VCC

: The domestic hot water rotary knob is used to set

the cylinder temperature if a domestic hot water cylinder is
connected.

VCW

: The domestic hot water rotary knob is used to set the

domestic hot water outlet temperature.

If a control is connected, the domestic hot water rotary knob
should be turned clockwise as far as it will go. The control
then determines the cylinder temperature.

Summary of Contents for atmoTEC exclusive

Page 1: ...ing instructions atmoTEC exclusive atmoTEC plus VC VCC VCW DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Page 2: ...2 Storing documents 6 2 3 Validity of the instructions 6 3 Product description 6 3 1 Overview of the control elements 6 3 2 Information on the data plate 7 3 3 CE label 8 4 Operation 8 4 1 Opening th...

Page 3: ...e product and any other system components compliance with all inspection and main tenance conditions listed in the instruc tions This product can be used by children aged from 8 years and above and pe...

Page 4: ...es to the entire flue system to the expansion relief valve to the drain pipework to constructional conditions that may affect the operational reliability of the product 1 8 Risk of poisoning caused by...

Page 5: ...is a risk of calcification in products which generate hot water Set the hot water temperature to a max imum of 50 C 1 13 Risk of material damage caused by frost Ensure that the heating installation al...

Page 6: ...the control elements E bar 3 1 2 4 5 6 7 8 9 10 1 Display 2 i button 3 Control accessory 4 Manometer 5 Main switch 6 button 7 button 8 Reset button 9 Heating flow temperat ure rotary knob 10 Domestic...

Page 7: ...c hot water cylinder is enabled by the control and floor standing boiler control system Symbol flashes Do mestic hot water cyl inder is being heated VCW Symbol permanently visible Domestic hot water i...

Page 8: ...he gas stopcock on the product 4 Open the service valves in the heating installation s flow and return Applicability Product with integrated domestic hot water generation OR Product with connected dom...

Page 9: ...lue in the display flash ing If the level falls below 0 03 MPa 0 3 bar the system displays the fault message and F 22 alternately and the burner is blocked If the system pressure is lower than 0 06 MP...

Page 10: ...te The maximum heating flow temperature is set in the factory at 75 C This can be defined by the competent person to be between 40 C and 85 C 4 10 Setting the domestic hot water generation 4 10 1 Sett...

Page 11: ...water rotary knob 1 clockwise as far as it will go setting a Set the rotary knob to the required domestic hot water temperature e g setting b The keep warm temperature is automatically ad justed to t...

Page 12: ...ng mode and leave the heating flow temperature rotary knob 1 at the clockwise end stop Conditions No control connected E bar 1 To switch off heating mode turn the heating flow tem perature rotary knob...

Page 13: ...switch 2 Heating flow temperat ure rotary knob 3 Domestic hot water rotary knob 1 Turn the domestic hot water rotary knob 3 anti clock wise as far as it will go 2 Turn the rotary knob for the heating...

Page 14: ...y contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 10 Guarantee and customer service 10 1 Guarantee H...

Page 15: ...ct switches on automatically when the power is restored The product is switched off Switch on the product Switching on the product section The heating flow temperature is set too low or to the Heating...

Page 16: ...8 0 Telefax 021 91 18 2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or...

Reviews: