Product description 3

0020214277_01 atmoTEC exclusive, atmoTEC plus Operating instructions

7

3.1.1

Digital Information and Analysis System
(DIA)

1

2

1

Display showing the
current heating flow
temperature, the filling
pressure in the heating
installation, or a status
or fault code

2

Plain text display (for
atmoTEC exclusive
only)

Symbol

Meaning

Explanation

Flue gas route

Symbol permanently
visible: Fault in the flue
gas route

VR 920

The heating flow and
domestic hot water tem-
perature are specified
via the

VR 920

commu-

nications system. The
product works at temper-
atures other than those
set at the rotary knob.
This operating mode can
only be terminated by:

VR 920

Changing the tem-
perature at the rotary
knobs by more than

±

5 K

This operating mode
cannot be terminated
by:

Pressing the

Reset

button.

Switching the
product off and on
again

Heating mode

Symbol perman-
ently on: Product is
in heating mode op-
erating mode

Symbol flashing:
Burner anti-cycling
time is active

Symbol

Meaning

Explanation

Domestic hot water gen-
eration

VC/VCC*:

Symbol perman-
ently visible: Char-
ging mode for the
domestic hot water
cylinder is enabled
by the control and
floor-standing boiler
control system

Symbol flashes: Do-
mestic hot water cyl-
inder is being heated

VCW:

Symbol permanently
visible: Domestic hot
water is being drawn
off

Symbol off: No do-
mestic hot water is
being drawn off

Warm start

VCW

:

Symbol permanently
visible: Warm start
function is in standby

Symbol flashes:
Warm start function
is in standby, burner
is switched on

Heating pump operating

Solenoid valve is actu-
ated

Gas supply to the burner
is open

Current energy demand

Display of the current
burner modulation rate
(only bar graph display
for atmoTEC exclusive)

Fault during burner oper-
ation

Burner is switched off

Burner operating cor-
rectly

Burner is switched on

* Only when a domestic hot water cylinder is connected

Press the "-" button for approx. five seconds to switch from the
flow temperature display to the system pressure display or vice-
versa.

3.2

Information on the data plate

The data plate is mounted on the underside of the product at
the factory.

Information on the data
plate

Meaning

VC, VCC, VCW

Type designation

10, 19, 20, 24, 25

Unit output

/4

Unit generation

-5 = plus, -7 = exclusive

Unit type

V

Mains voltage

W

Power consumption

Hz

Mains frequency

MPa

Max. line pressure

IP

IP rating/protection class

Cat. (e.g. II

2H3P

)

Unit category

Summary of Contents for atmoTEC exclusive

Page 1: ...ing instructions atmoTEC exclusive atmoTEC plus VC VCC VCW DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Page 2: ...2 Storing documents 6 2 3 Validity of the instructions 6 3 Product description 6 3 1 Overview of the control elements 6 3 2 Information on the data plate 7 3 3 CE label 8 4 Operation 8 4 1 Opening th...

Page 3: ...e product and any other system components compliance with all inspection and main tenance conditions listed in the instruc tions This product can be used by children aged from 8 years and above and pe...

Page 4: ...es to the entire flue system to the expansion relief valve to the drain pipework to constructional conditions that may affect the operational reliability of the product 1 8 Risk of poisoning caused by...

Page 5: ...is a risk of calcification in products which generate hot water Set the hot water temperature to a max imum of 50 C 1 13 Risk of material damage caused by frost Ensure that the heating installation al...

Page 6: ...the control elements E bar 3 1 2 4 5 6 7 8 9 10 1 Display 2 i button 3 Control accessory 4 Manometer 5 Main switch 6 button 7 button 8 Reset button 9 Heating flow temperat ure rotary knob 10 Domestic...

Page 7: ...c hot water cylinder is enabled by the control and floor standing boiler control system Symbol flashes Do mestic hot water cyl inder is being heated VCW Symbol permanently visible Domestic hot water i...

Page 8: ...he gas stopcock on the product 4 Open the service valves in the heating installation s flow and return Applicability Product with integrated domestic hot water generation OR Product with connected dom...

Page 9: ...lue in the display flash ing If the level falls below 0 03 MPa 0 3 bar the system displays the fault message and F 22 alternately and the burner is blocked If the system pressure is lower than 0 06 MP...

Page 10: ...te The maximum heating flow temperature is set in the factory at 75 C This can be defined by the competent person to be between 40 C and 85 C 4 10 Setting the domestic hot water generation 4 10 1 Sett...

Page 11: ...water rotary knob 1 clockwise as far as it will go setting a Set the rotary knob to the required domestic hot water temperature e g setting b The keep warm temperature is automatically ad justed to t...

Page 12: ...ng mode and leave the heating flow temperature rotary knob 1 at the clockwise end stop Conditions No control connected E bar 1 To switch off heating mode turn the heating flow tem perature rotary knob...

Page 13: ...switch 2 Heating flow temperat ure rotary knob 3 Domestic hot water rotary knob 1 Turn the domestic hot water rotary knob 3 anti clock wise as far as it will go 2 Turn the rotary knob for the heating...

Page 14: ...y contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 10 Guarantee and customer service 10 1 Guarantee H...

Page 15: ...ct switches on automatically when the power is restored The product is switched off Switch on the product Switching on the product section The heating flow temperature is set too low or to the Heating...

Page 16: ...8 0 Telefax 021 91 18 2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or...

Reviews: