1 Safety

4

Operating instructions atmoTEC exclusive, atmoTEC plus 0020214277_01

Warn other occupants in the building by
yelling or banging on doors or walls.

Leave the building immediately and ensure
that others do not enter the building.

Alert the police and fire brigade as soon as
you are outside the building.

Use a telephone outside the building to
inform the emergency service department
of the gas supply company.

1.5

Risk of death due to blocked or
leaking flue pipework

What to do if you smell flue gas in the prop-
erty:

Open all accessible doors and windows
fully to provide ventilation.

Switch off the product.

Inform a competent person.

1.6

Risk of death due to explosive and
flammable materials

Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).

1.7

Risk of death due to changes to the
product or the product environment

Never remove, bridge or block the safety
devices.

Do not tamper with any of the safety
devices.

Do not damage or remove any tamper-
proof seals on components.

Do not make any changes:

The product itself

to the gas, supply air, water and electri-
city supply lines

to the entire flue system

to the expansion relief valve

to the drain pipework

to constructional conditions that may
affect the operational reliability of the
product

1.8

Risk of poisoning caused by
insufficient combustion air supply

Conditions

: Open-flued operation

Ensure that there is a sufficient combus-
tion air supply.

1.9

Risk of being scalded by hot drinking
water

There is a risk of scalding at the hot water
draw-off points if the hot water temperatures
are greater than 60 °C. Young children and
elderly persons are particularly at risk, even
at lower temperatures.

Select the temperature so that nobody is at
risk.

1.10 Risk of injury and material damage

due to maintenance and repairs
carried out incorrectly or not carried
out at all

Never attempt to carry out maintenance
work or repairs on your product yourself.

Faults and damage should be immediately
rectified by a competent person.

Adhere to the maintenance intervals spe-
cified.

1.11 Risk of corrosion damage due to

unsuitable combustion and room air

Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the air/flue
pipe.

Ensure that the combustion air supply is
always free of fluorine, chlorine, sulphur,
dust, etc.

Ensure that no chemical substances are
stored at the installation site.

Summary of Contents for atmoTEC exclusive

Page 1: ...ing instructions atmoTEC exclusive atmoTEC plus VC VCC VCW DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Page 2: ...2 Storing documents 6 2 3 Validity of the instructions 6 3 Product description 6 3 1 Overview of the control elements 6 3 2 Information on the data plate 7 3 3 CE label 8 4 Operation 8 4 1 Opening th...

Page 3: ...e product and any other system components compliance with all inspection and main tenance conditions listed in the instruc tions This product can be used by children aged from 8 years and above and pe...

Page 4: ...es to the entire flue system to the expansion relief valve to the drain pipework to constructional conditions that may affect the operational reliability of the product 1 8 Risk of poisoning caused by...

Page 5: ...is a risk of calcification in products which generate hot water Set the hot water temperature to a max imum of 50 C 1 13 Risk of material damage caused by frost Ensure that the heating installation al...

Page 6: ...the control elements E bar 3 1 2 4 5 6 7 8 9 10 1 Display 2 i button 3 Control accessory 4 Manometer 5 Main switch 6 button 7 button 8 Reset button 9 Heating flow temperat ure rotary knob 10 Domestic...

Page 7: ...c hot water cylinder is enabled by the control and floor standing boiler control system Symbol flashes Do mestic hot water cyl inder is being heated VCW Symbol permanently visible Domestic hot water i...

Page 8: ...he gas stopcock on the product 4 Open the service valves in the heating installation s flow and return Applicability Product with integrated domestic hot water generation OR Product with connected dom...

Page 9: ...lue in the display flash ing If the level falls below 0 03 MPa 0 3 bar the system displays the fault message and F 22 alternately and the burner is blocked If the system pressure is lower than 0 06 MP...

Page 10: ...te The maximum heating flow temperature is set in the factory at 75 C This can be defined by the competent person to be between 40 C and 85 C 4 10 Setting the domestic hot water generation 4 10 1 Sett...

Page 11: ...water rotary knob 1 clockwise as far as it will go setting a Set the rotary knob to the required domestic hot water temperature e g setting b The keep warm temperature is automatically ad justed to t...

Page 12: ...ng mode and leave the heating flow temperature rotary knob 1 at the clockwise end stop Conditions No control connected E bar 1 To switch off heating mode turn the heating flow tem perature rotary knob...

Page 13: ...switch 2 Heating flow temperat ure rotary knob 3 Domestic hot water rotary knob 1 Turn the domestic hot water rotary knob 3 anti clock wise as far as it will go 2 Turn the rotary knob for the heating...

Page 14: ...y contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 10 Guarantee and customer service 10 1 Guarantee H...

Page 15: ...ct switches on automatically when the power is restored The product is switched off Switch on the product Switching on the product section The heating flow temperature is set too low or to the Heating...