B
Connection diagram
L1
N
L3
L2
X11
X2
X8
X4
X3
BUS
X6
T10
X5
T9
X1
X9
F3 T2
PE
PE
N
N
PE
N
L2
L1
N
L3
F2 T2
230V
24V
K2
K3
K1
K200
1
2
15
3
4
6
7
8
9
14
5
13
12
10
11
1
Air inlet temperature sensor
2
Hot brine temperature sensor
3
Fan control line
4
Fan voltage supply
5
F3 T2 fuse
6
Connection option: Condensate tray heating
7
Connection option: Safety cut-out
8
Safety cut-out with temperature switch and thermal
fuse
9
Heating element de-icer
10
Connection box
11
Line protection switch
12
Mains connection
13
F2 T2 fuse
14
Control unit
15
Address switch: Address 1 (
≤
10 kW), address 1/2
(>10 kW)