Installation instructions geoTHERM VWS/VWW 0020057444_01
Electrical circuit diagram - VWW
1
LL
L
L
L
1
L
NNNN
N
2
N
2
1
2
1
NL
23
4
5
S
C
H
6
7
8
AS
B
NN
Au
f
Zu
L
N
12
12
12
12
12
12
DCF
O
T
AF
-
+
Au
f
Zu
ZH
N
L
ZP
N
L
SK2
-P
N
L
HK2
-P
H
K2
VF2
RF1
VF1
S
P
B
US
DCF
/A
F
E
VU
1xZP
LP
/UV 1
L3
L2
L1
L3
L3
L3
L2
L1
N
N
N
N
AZ
N
L2
L1
L3
N
ABB A12-30-01
T1
T2
T3
A2
A1
L1
L2
L3
L3
L2
L1
L3
L2
L1
L1
L2
L3
N
ABB A9-30-01
T1
T2
T3
T1
E 16 DU
T2
T3
A2
A1
L1
L2
L3
T1
black
yellow-green
yellow-green
rot
rot
brown
blue
yellow-green
yellow-green
black
orange
brown
grey
yellow-green
yellow-green
blue
blue
blue
blue
blue
blue
grey
grey
grey
grey
grey
brown
brown
brown
brown
black
black
blue
grey
brown
black
black
black
blue
orange
orange
white
white
black
brown
PE
N
L
3
L
2
L
1
Main
power inlet
3 x 400 V PE N
Electric
auxiliary
heating
vrnetDIALOG
(optional)
Links for starting
current limiter
STB
Heating
pump
Flow monitor
High pressure
switch
Low pressure
switch
Temperature sensors
Pressure sensors
Fuse
T4A/250 V
Fuse
T4A/250 V
Phase
monitoring
Diverter valve
Heating
(internal)
Diverter valve
Heating / Hot water
(customer side)
PE
N
L
3
L
2
L
1
Well pump
(customer side)
Fig. 4, Appendix, Electrical circuit diagram - VWW