Installation instructions geoTHERM VWS/VWW 0020057444_01
54
Display shown
Description
Factory setting
DHW
4
Parameters
Hot water mode
>Auto
Max. DHW temp.
60 °C
Min. DHW temp.
44 °C
Current DHW temp.
51 °C
Select flow temperature
The auto, on, and off operating modes are possible
for the connected domestic hot water cylinders and
the circulation circuit:
The
maximum DHW temperature
determines the
temperature to which the domestic hot water cylin-
der should be heated.
The
minimum DHW temperature
determines the
limit below which the domestic hot water cylinder is
heated.
Note:
The maximum DHW temperature is only dis-
played when the auxiliary hot water heating is ena-
bled (see Menu C7). Without electric auxiliary heat-
ing, the DHW temperature is limited by the pressure
sensor control shut-off in the cooling circuit and
cannot be adjusted!
Current DHW temp.
: Current temperature in the do-
mestic hot water cylinder
Min. hot water
temp. 44 °C
<HK2>
5
Time programme
>Mo
1
00:00
24:00
2
:
:
3
:
:
>Select day of the week
You can set the heating times for each heating cir-
cuit in the
HK2 timer program
menu.
Up to three heating times can be programmed per
day or block. The control system operates according
to the heating curve and the room setpoint tempera-
ture.
Mon – Fri 0:00 –
24:00
DHW loading
5
Time programme
>Mo
1
06:00
22:00
2
:
:
3
:
:
>Select day of the week
You can set the times at which the domestic hot
water cylinder is heated in the
DHW timer program
menu.
Up to three times can be programmed per day or
block.
Mon – Fri 6:00 –
22:00
Sat 7:30
–
23:30
Su. 7:30
–
22:00
Circulation pump
5
Time programme
>Mo
1
06:00
22:00
2
:
:
3
:
:
>Select day of the week
You can set the times at which the circulation pump
is to be operational in the
Circulation pump timer
program
menu.
Up to three times can be programmed per day or
block.
If the hot water mode (see Menu
3) is set to "ON",
the circulation pump runs constantly.
Mon – Fri 6:00 –
22:00
Sat 7:30
–
23:30
Su. 7:30
–
22:00
Table 8.3 Parameters that can be set in the Operator level
(cont.)
8 Controller