Installation instructions geoTHERM VWS/VWW 0020057444_01
78
Description
Unit
VWW 61/2
VWW 81/2
VWW 101/2
VWW 141/2
VWW 171/2
refrigerant circuit
- Coolant type
-
R 407 C
- Quantity
kg
1.9
2.2
2.05
2.9
3.05
- Permissible operating overpressure
- Compressor type
- Oil
MPa (bar)
-
-
2.9 (29)
Scroll
Ester
Heat pump performance data
W10W35 dT5
- Heating output
- Power consumption
- Performance figure/COP
W10W35 dT10
- Heating output
- Power consumption
- Performance figure/COP
W10W55
- Heating output
- Power consumption
- Performance figure/COP
kW
kW
-
kW
kW
-
kW
kW
-
8.2
1.6
5.2
8.5
1,5
5.6
7.5
2.3
3.3
11.6
2.1
5.5
11.6
2.1
5.7
10,2
3.0
3.5
13.9
2.6
5.3
14.0
2.5
5.5
13.3
3.5
3.8
19.6
3.7
5.3
20.1
3.5
5.7
19.2
5.1
3.8
24.3
4.6
5.3
23.9
4.3
5.6
23.4
5.9
3.7
Internal sound level
dbA
46
48
50
52
53
Conforms to safety regulations
-
CE mark
Low Voltage Directive 73/23/EWG
EMC Directive 89/336/EWG
EN 60335
ISO 5149
Table 13.2 Technical data - VWW (cont)