VAG Operation and Maintenance Instructions • 8

4.5  Assembly instructions and fittings

Check the valve for possible damage that it may have suffe-

red during transport and storage. Protect the valve against dirt 

caused on the construction site by adequate covering until ins-

tallation. Thoroughly clean the surface of the flange gasket prior 

to installation.

VAG does not assume any liability for consequential damage 

caused by dirt, shot-blasting gravel residue etc.

The functional parts should be checked for proper operation prior 

to installation.

Should the valves be repainted later on, it must be ensured  that 

no paint is applied to the functional parts. The identification plates 

must not be painted over either. If the equipment is sand-blasted 

for cleaning prior to installation, these parts must be adequately 

covered. If solvents are used for cleaning, it must be ensured that 

the solvents do not destroy the seals of the pipeline or the valve.

For the assembly of the VAG DUOJET

®

 Automatic Air Valve it 

must be ensured that proper load suspension devices as well as 

means of transport and lifting devices are available.

When connecting the valve with the pipeline flanges, hexagon 

bolts and nuts with washers from flange to flange must be used 

in the through holes.

The bolts and nuts selected by the operator must be appropriate 

for the pressure, temperature, flange material and the gasket. For 

connections that contain at least one cast-iron flange it is recom-

mended to use bolts with a yield strength not exceeding 240 N/

mm².

Fasten the bolts evenly and diagonally to prevent unnecessary 

tension and the resulting cracks or breaks.

We recommend using steel-reinforced rubber seals to DIN EN 

1514-1 Shape IBC. If you use raised face flanges, these seals are 

mandatory.

5  Set-up and operation of the valve

5.1  Visual inspection and preparation

Before putting the valve and the equipment into operation, per-

form a visual inspection of all functional parts. Check whether all 

bolted connections have been properly fastened.

If there is an upstream stop valve this must be set to the open po-

sition so that the VAG DUOJET

®

 Automatic Air Valve can function 

satisfactorily.

5.2  Function check and pressure test

Warning:

 The pressure exerted on the closed valve 

must not exceed its nominal pressure (see technical 

data sheet KAT 1912-A).

Newly installed pipeline systems should first be thoroughly pur-

ged to remove all foreign particles. If residue or dirt particles are 

present in the pipeline, they may clog the installation while the 

pipeline is being purged. This may impair the function of the valve 

or even block it.

In particular after repair work or upon the commissioning of new 

equipment, the pipeline system is to be purged again with the val-

ve being fully open. If detergents or disinfectants are used it must 

be ensured they do not attack the valve materials.

6  Maintenance and repair

6.1  General safety instructions

Prior to beginning inspection and maintenance work on 

the valve, the connection to the pressure carrying pipe-

line must be shut off and depressurized via the plug on 

the valve. Only afterwards may maintenance work on 

the valve be performed.

After completing the maintenance works and before resuming 

operation, check all connections for proper fastening and tight-

ness. Perform the steps described for initial set-up as described 

under Section 5 “Set-up and operation”.

Statutory and local provisions as well as the safety and accident 

prevention regulations must be observed and complied with at all 

times.

Servicing, maintenance and inspection work as well as the repla-

cement of spare parts must only be carried out by qualified staff. 

The plant operator is responsible for determining the suitability of 

the staff or for ensuring the relevant qualifications.

In case the operator’s employees do not have the qualifications 

required, they need to attend a training course. This training 

course can e.g. be held by VAG Service employees.

In addition to this, the plant operator needs to ensure that all em-

ployees have understood these Operation and Maintenance Inst-

ructions as well as all further instructions referred to in them.

Protective equipment such as safety boots, safety helmets, gogg-

les, protective gloves etc. must be worn during all work requiring 

such protective equipment or for which such protective equip-

ment is prescribed.

Improper or wrong use of the valve should be avoided. Prior to the 

performance of any work on the valve and equipment it must be 

ensured that the relevant pipeline section has been depressurised 

and/or de-energised.

6.2  Inspection and operation intervals

The VAG DUOJET

®

 Automatic Air Valve is virtually maintenance-

free.

The valve should however be inspected within a period of one 

year (DVGW data sheet W 392).

Under extreme conditions of use this inspection interval should be 

carried out more frequently.

Before any maintenance work is performed on the VAG DUOJET

® 

Automatic Air Valve, the valve must be shut off by an inspection 

valve and must be depressurised using the threaded plug 11 (see 

Section 6.3.1. “Design”).

Summary of Contents for DUOJET Series

Page 1: ...KAT B 1912 Edition2 01 18 Operation and Maintenance Instructions VAG DUOJET Automatic Air Valve...

Page 2: ...nstallation note 6 4 4 1 Installation position downstream from pumps 7 4 4 2 Installation in standpipes 7 4 4 3 Discharging splashing or surge water 7 4 5 Assembly instructions and fittings 8 5 Set up...

Page 3: ...ng pressure medium temperature please refer to the product rela ted documentation KAT 1912 A For any alternative operating conditions and applications the manufacturer s written approval must be obtai...

Page 4: ...waste water For information about the corresponding temperature limits please refer to the product related technical documentati on KAT A 1912 In case of alternative operating conditions and applicat...

Page 5: ...e performance data The small venting cross section is for venting small amounts of air during operation under full internal overpressure Picture 6 Air release small cross section Installation should t...

Page 6: ...y 600 mm DN 600 1 2 3 4 1 Venting valve 2 Manually operated air inflow and release flush valve 3 Central stop valve 4 Additional flush and discharge valve 4 2 3 Water flow rate The water flow rate asc...

Page 7: ...ities during the filling process If the VAG DUOJET Automatic Air Valve is installed directly on the standpipe there is a risk of the ball closing prematurely To prevent premature closing we recommend...

Page 8: ...sidue or dirt particles are present in the pipeline they may clog the installation while the pipeline is being purged This may impair the function of the valve or even block it In particular after rep...

Page 9: ...shaft as well as drain Condition of measures for thermal insulation Condition of additional protective measures against infiltration of dirt microbes and rain water in the shaft 6 3 1 Design The desig...

Page 10: ...disassemble and remove foreign matter Internal pressure too low To achieve tightness internal pressure must be at least 3 m water column Replace gasket with a low pressure gasket 0 1 1 bar Deposits f...

Page 11: ...Edition2 01 2018 VAG GmbH Carl Reuther Str 1 68305 Mannheim Germany Tel 49 621 749 0 Fax 49 6 21 749 2153 info vag group com www vag group com...

Reviews: