18
7.5 EXPLANATION OF THE MENUS
The Bridge Panel PC is divided into 5 sub
menu’s: ShaPoLi, Event Logs, Alarms, Signals and Settings.
By touching the relevant tab, the specific menu will be displayed.
7.5.1 ShaPoLi Home screen
By touching the
ShaPoLi
tab in the top left corner you will be guided to the ShaPoLi home screen. The
ShaPoLi home screen is showing all important actual information regarding Shaft Power Limitation. The
actual shaft power indicator is visualised on the left. On the right the actual Shaft Speed, actual Shaft
Power and the EEXI Power limit are indicated.
In every sub
menu except “Settings”, the current status of the system can be seen via the ShaPoLi bar.
A
green
ShaPoLi bar shows that the actual shaft power is below the EEXI limit, and no other alarms are
present.
Figure 12
– ShaPoLi home screen – Power below limit
The green bar in the ShaPoLi home screen will change to
red
when one of the following alarms occur:
-
Power is over the EEXI Shaft Power Limit
-
T-Sense/TT-sense (over MODBUS) communication failure
-
NMEA communication failure
-
Some of the expected power sensors have not been enabled
-
Individual sensor (Torque, Speed, Power) communication failure if using an analogue power
sensor
-
Missing encrypted ShaPoLi settings
-
IO communication failure
The message in the red bar depends on the alarm. The speaker in the Bridge Panel PC will be activated
for half a second, every second and the SDB-3 software starts logging immediately. The Digital Output
which is Normally Closed, will open. The tabs “ShaPoLi” and “Alarms” will be coloured red and will blink.