44 • vacon
appendices
Tel.+358-(0)201-21
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
11
11.
APPENDICES
appendix a - device profile for drives
Vacon CanOpen option board follows the Drive device profile DSP-402. The Velocity mode is
supported.
Basic Device Control and Device Data Interface
vl_velocity_deceleration (6049h)
vl_velocity_acceleration (6048h)
vl_velocity_demand (6043h) RPM
vl_velocity_min_max_amount
(6046h)
%torque (2003h)
%current (2004h)
fault code (2063h)
vl_target_velocity (6042h) RPM
Drive Interface
Limit
Ramp
Motor
vl_control_effort (6044h) RPM
RPM to %
RPM to Hz
RPM to Hz
RPM to Hz
% to RPM
RPM to %
ActualSpeed
MinFrequency
MaxFrequency
DecelerationTime
AccelerationTime
FaultCode
controlword (6040h)
Application
RUN/STOP, FAULT
RUN/STOP,READY,FAUL
statusword (6041h)
State
Machine
MotorTorque
MotorCurrent