4.3
LED indications
The CanOpen Option Board includes two LED status indicators next to the connector: Fieldbus status
(M), CanOpen(A). Led N is unused.
Figure 4-2. LED indications on the CANopen board
CanOpen board status LED (A) GREEN
LED is:
Meaning:
OFF
Option board not activated
ON
Option board in initialisation state waiting for activation
command from the frequency converter
Blinking fast
(1 blink / s)
Option board is activated and in RUN state
Option board is ready for external communication
Blinking slow
(1 blink/ 5s)
Option board is activated and in FAULT state
Internal fault of option board
Fieldbus status LED (M) GREEN
LED is:
Meaning:
OFF
Fieldbus module is waiting for parameters from the
frequency converter
No external communication
ON
Fieldbus module is activated
Parameters received and module activated
Module is waiting for messages from the bus
Blinking fast
(1 blink / s)
Module is activated and receiving messages from the bus
Blinking slow
(1 blink / 5s)
Module is in FAULT state
No messages from Master within the watchdog time
Bus broken, cable loose or Master off line