ELECTRICAL CONNECTION
Tel. +358 (0) 201 2121 • Fax +358 (0)201 212 205
The minimum cable cross section is calculated in compliance with loading capacity of cables. The
recommended cross section is calculated in compliance with 1-% voltage drop for a cable 100 m in
length on DC-side and 50 m in length on AC-side.
NXV0800
15x 2x95mm
2
16x 2x95mm
2
32x 2x185mm
2
NXV1000
19x 2x95mm
2
20x 2x95mm
2
32x 2x185mm
2
NXV1200
23x 2x95mm
2
24x 2x95mm
2
32x 2x185mm
2
Table 7. Panel output cable dimensions
Model
Minimum cross
section
Recommended cross
section
Maximum cross section
NXV0125
2x 3x95mm
2
2x 3x120mm
2
2x 3x240mm
2
NXV0200
3x 3x95mm
2
2x 3x185mm
2
4x 3x240mm
2
NXV0400
6x 3x95mm
2
4x 3x185mm
2
12x 3x240mm
2
NXV0600
9x 3x95mm
2
6x 3x185mm
2
12x 3x240mm
2
NXV0800
12x 3x95mm
2
8x 3x185mm
2
16x 3x185mm
2
NXV1000
15x 3x95mm
2
10x 3x185mm
2
16x 3x185mm
2
NXV1200
17x 3x95mm
2
2x 3x185mm
2
16x 3x185mm
2
Table 8. Panel earthing cable
dimensions
Model
Cross section
NXV0125
50mm
2
NXV0200
50mm
2
NXV0400
50mm
2
NXV0600
50mm
2
NXV0800
50mm
2
NXV1000
50mm
2
NXV1200
50mm
2
Table 6. Panel input cable dimensions
Model
Minimum cross section
Recommended cross section
Maximum cross section