BH Application vacon • 2
Service support: find your nearest Vacon service center at www.vacon.com
1
1.
BH A
PPLICATION
The VACON
®
20 CP/X drive with +D option contains a preloaded application for instant use.
The parameters of this application are listed in chapter 2.2 of this manual and explained in
more detail in chapter 2.
1.1
Specific functions of Vacon BH application
The Vacon BH application allows flexible use of VACON
®
20 CP/X frequency converters.
The visibility of parameters and monitors is arranged in three access levels, selected by pa-
rameter P14.1.
Basic
:
•
Monitor of ASi inputs and outputs (only with +D option and AS-interface connection)
•
Monitor of sensors
•
Monitor of main motor variables
•
Setting of motor data
•
Setting of Run control mode and commonly used speed reference
•
Setting of basic ramp times
•
Setting of quick stop function
•
Setting of ASi inputs and outputs functions
Advanced
:
•
Basic + Monitor of more drive/motor variables
•
More options for Start/stop and reference selection
•
Setting of a second set of ramp times
•
Setting of advanced motor control
•
Setting of mechanical brake control
•
Setting of protections and autoreset
Service
:
•
Ad Monitor of drive internal I/Os
•
Setting of some extra motor control and protections features
•
Setting of analogue and relay outputs
1)
1)
terminals of analogue output and relays are not accessible in standard Vacon 20 CP/X+D
drive.
Code
Parameter
Min
Max
Default
ID
Description
P14.1
Parameter access level
0
2
0
115
0 = Basic
1 = Advanced
2 = Service
P14.2
Parameter lock
0
1
0
1805
0= Edit Enable
1= Edit Disable
Summary of Contents for 20 SERIES