Description of Groups
vacon • 18
Service support: find your nearest Vacon service center at www.vacon.com
2
P3.19
MANUAL
Reference selection
0
2
1
3)
1820
Advanced
Selection of MANUAL
reference source:
0 = Manual Preset
speed
1 = Panel potentiom-
eter
2 = Manual Preset
speed + Panel Poten-
tiometer Correction
P3.20
Manual Preset speed
0.00
P3.2
Hz
50.00
131
Basic
P3.21
Panel Potentiometer
Min. Frequency
0.00
P3.21
Hz
0.0
1865
Advanced
Minimum freq. refer-
ence from potenti-
ometer
P3.22
Panel Potentiometer
Max. Frequency
P3.20
P3.2
Hz
50.00
1866
Advanced
Maximum freq.refer-
ence from potenti-
ometer
P3.23
Panel Potentiometer
Min. Correction
-100.00
0.00
%
-10.00
1894
Advanced
Ref adjust at mini-
mum potentiometer
signal
P3.24
Panel Potentiometer
Max. Correction
0.00
100.00
%
10.00
1895
Advanced
Ref adjust at maxi-
mum potentiometer
signal
NOTE!
1)
Selection 2 is available only if ASi board is not installed. In this case a different
fieldbus can be used to control the reference.When ASi board is installed this
parameter is automatically set to 0.
2)
In AUTO mode, preset speed 1-8 can be directly activated by ASi outputs or
Sensors signals, independently from P3.3 setting.
If P3.3 = 1 and the reference is restored to motor potentiometer, after a preset
speed, P3.17 defines the initial value for the reference.
3)
When ASi board is installed this parameter is automatically set to 0.
Table 32: Group References.