2. Door switch function
When the door switch is opened and la
st
s for more than 1 minute, the door open-
ing alarm will be prompted. At this time, the buzzer will buzz at an interval of 1
second/time, and the display board will display the "do" code. When the door
switch is closed, the fault will be removed and the buzzer and the display of fault
code will be canceled.
Note: Press any key to mute, and the fault code will still be displayed.
3. Lighting function
Short press the "Light on/o
ff
" key to turn on the "Light" indicator light of the display
and control board and the lighting light of the refrigerator compartment; then short
press the "Light on/o
ff
" key to turn o
ff
the "Light" indicator light of the display and
control board and the lighting light of the refrigerator compartment.
Note: The lighting function is independent and is not a
ff
ected by key lock and
temperature sensor fault.
User parameter table
Parameter
number
Description
Scope
Note
Default 5.0°C
Default 3.0
Set the temperature of
Default 3.0
Pharmacy refrigerator chamber
2-8
℃
0.0~10.0
℃
0.0 Cancel the alarm
0.0~10.0
℃
0.0 Cancel the alarm
High temperature alarm value
Low temperature alarm value
SEt
L1
H1
The set temperature range of the Pharmacy refrigerator chamber is 2-8°C. When
the set range exceeds the limit, a "beep" prompt tone will be generated.
Note: 1. When the parameter number is displayed in the user menu, press the
"UP" or "DOWN" key to display the parameter number circularly.
For example: press the "DOWN" key to display "SEt -> H1 -> L1 -> SEt" the
parameter numbers in sequence, and press the "UP" key to cycle in the reverse
direction.
2. Under the user menu, if there is no key operation within 10s, the user menu is
automatically exited and the amended parameter values are saved.