Maintenance and care

Warning

  T o prevent electric shock or personal injuries, please make sure that power 

is disconnected before having any repairs or maintenance on the device.

 W

  hen maintaining the device, make sure that you do not inhale surrounding 
medications or suspended particles that could damage your health.

Note

 D

  o not directly sprinkle water on the box, so as to avoid the decline of 
insulation performance of electrical components and rust of metal parts.

 D

  o not use hot water, corrosive detergent or organic solvent to clean the 
cabinet.

  Do not put heavy objects on the top of the device to avoid deformation of 

the device under pressure.

Defrosting: The device will automatically defrost during the working process, 

Device maintenance

which is convenient to use.
Cleaning and maintenance:

  The device shall be cleaned once a month. Regular cleanings can keep the 

pharmacy refrigerator fresh.

 U

  se a dry cloth to wipe off a small amount of dust outside and inside of the 
pharmacy refrigerator as well as that on all accessories. If the pharmacy 
refrigerator is dirty, use a cleaning cloth soaked with neutral detergent to 
 remove the stolen goods, wipe off the residual detergent with a wet cloth,
and then wipe it again with a dry cloth.

 D

  o not dump water on the shell of the pharmacy refrigerator or inside 
the pharmacy refrigerator, otherwise the insulation of electrical  
appliances may be damaged and faults may occur.

  The compressor and other mechanical parts are completely sealed without 

lubrication.

Deactivation:  If the device is stored in an unsupervised area for a long time 

Device deactivation

and is not used, the power supply should be cut off and the inner 
and outer surfaces of the box should be wiped clean with a warm 
and wet soft cloth, and then dried and sealed; It is necessary to 
ensure that the device is locked, and that children cannot open 
the door to prevent accidents such as suffocation.

19

Summary of Contents for VS350

Page 1: ...com au Warning Before using this product please read this manual carefully and keep it for future reference The design and speci cations are subject to change without prior notice for product improve...

Page 2: ...nings 1 Precautions and safety measures 3 Precautions for use 8 Product installation 9 Product compositions and overview 14 Operating instruction 15 Maintenance and care 19 Speci cations 21 Packing li...

Page 3: ...cture Refrigerant Tubing CAUTION Risk Of Fire Or Explosion Flammable Refrigerant Used Consult Repair Manual Owner s Guide Before Attempting To Install Or Service This Equipment All Safety Precautions...

Page 4: ...ondenser fan and evaporator fan with vortex e ect refrigeration is adopted with stable lasting performance and low noise Ensures that the temperature in the cabinet is more uniform and stable and the...

Page 5: ...ing matters highlighted in warning signs may cause serious casualties or damages to the pharmacy refrigerator and related property losses Behavior or operation that must be observed Product with the s...

Page 6: ...k Please use the special power supply indicated on the nameplate of the pharmacy refrigerator otherwise it may cause re or electric shock If the voltage is lower than 187 V or higher than 242 V it is...

Page 7: ...not used for a long time unplug the power plug to prevent electric shock leakage or res caused by the aging power cord If the pharmacy refrigerator is idle for a long time in an unsupervised area mak...

Page 8: ...pharmacy refrigerator by themselves Otherwise it may cause res or personal injuries due to improper operations Do not ground the pharmacy refrigerator through gas pipe power supply pipe telephone line...

Page 9: ...ng the sharp edges or corners and injuries to personnel Hold the handle to close the door so that the door will not catch your ngers When moving pharmacy refrigerators the inclination angle should not...

Page 10: ...lug the test hole with insulating material again otherwise the temperature in the box may not reach the set temperature value and condensation will appear around the outside of the through hole Please...

Page 11: ...bient temperature tolerance is within 16 C 32 C and recommended temperature is within 18 C 25 C If necessary air conditioning system should be used Environmental humidity lower than 80 Rh Avoid heavy...

Page 12: ...ensure that the input voltage requirements in the installation environment can be met Device shall be reliably grounded If the power cord socket is equipped with grounding wire check whether the grou...

Page 13: ...be left around the pharmacy refrigerator to facilitate ventilation and heat dissipation 4 Lock the front casters and adjust the adjustable feet optional Please rotate the adjustable feet clockwise to...

Page 14: ...perature and humidity of this product are di erent from the actual temperature and humidity in the box which is a normal phenomenon Please don t place items in the space between the bottom of the inne...

Page 15: ...letely closed Initial start up Please observe the following rules when conducting initial start up 1 Under no load condition please connect the power plug to right plugboard and the plugboard should n...

Page 16: ...heel Schematic Diagram VS350 Glass door lock Refrigeration air duct Refrigeration fan Glass door body Due to the improvement of the product and di erent models the actual product may be di erent from...

Page 17: ...ing the display board ashes at an interval of 1 second to display the set temperature value When a fault occurs the display board will display the fault code and if there are multiple faults the fault...

Page 18: ...ard shows the temperature in the Pharmacy refrigerator chamber In the case of unlocking 1 Press and hold the SET key for 3s and the digital tube ashes 1s inter val and displays the SEt parameter numbe...

Page 19: ...tment Note The lighting function is independent and is not a ected by key lock and temperature sensor fault User parameter table Parameter number Description Scope Note Default 5 0 C Default 3 0 Set t...

Page 20: ...t code and the buzzer will beep at an interval of 1 second Press any key to mute but the fault code will not disappear until the fault is removed The fault code and description are shown in the follow...

Page 21: ...gs can keep the pharmacy refrigerator fresh Use a dry cloth to wipe o a small amount of dust outside and inside of the pharmacy refrigerator as well as that on all accessories If the pharmacy refriger...

Page 22: ...quali ed professional recycling organizations for scrapping and disposal in accordance with local regulations and ordinances non professionals should not disassemble or decompose the device without a...

Page 23: ...ns 220 240V 50Hz 190W 1 0A MC 5L316B dB 316L VS350 Packing list The warranty card and certi cate are included in the instruction and the speci c packing list shall prevail in accordance with the real...

Page 24: ...Electrical schematic diagram Electrical schematic diagram of VS350 22...

Page 25: ......

Reviews: