background image

Precautions for use

  Before putting 

items

 into the device, please make sure that the 

internal 

temperature in the 

cabinet

 has reached the set temperature, and then put 

the 

items

 into the pharmacy refrigerator .i n batches.

 

The volume of the 

articles in the

 

box should not exceed 1/4 of its volume at a time to prevent 

the temperature

 

from rising too much.

  The temperature display value of the device is to show the temperature at 

the temperature sensor in the storage room. There is a certain difference 
between the displayed temperature and the actual temperature at the center 
of the device when the device just starts. As the device enters a stable state, 
the displayed temperature will gradually reach the actual temperature.

  The device box body is provided with a detection hole so as to lead out 

the test line in the box during the test. After the test line is led out, it is 
necessary to plug the test hole with insulating material again, otherwise 
the temperature in the box may not reach the set temperature value, and 
condensation will appear around the outside of the through hole.

  Please use diluted neutral cleaner to clean the device. Do not use brushes, 

acid, gasoline, soap powder, polishing agent or hot water to clean the 
device, otherwise the painted surface and plastic rubber parts may be 
damaged. Attention: Do not use volatile solvents such as gasoline to clean 

plastic and rubber parts.

  When the device is not in use for a long time, cut off the power supply and 
turn off the battery.

  Each time you access the items, please try to reduce the time to open the 

door to avoid large fluctuations in temperature and humidity inside the box.

  After the door is opened, the temperature inside the box will rise sharply in 

a short time. This is normal, and the situation will be restored within 1 hour 
after the door is closed.

  Under high temperature and high humidity environment, glass door may 

condense, which is normal phenomenon and does not affect the storage 
temperature in the box.  

8

Summary of Contents for VS350

Page 1: ...com au Warning Before using this product please read this manual carefully and keep it for future reference The design and speci cations are subject to change without prior notice for product improve...

Page 2: ...nings 1 Precautions and safety measures 3 Precautions for use 8 Product installation 9 Product compositions and overview 14 Operating instruction 15 Maintenance and care 19 Speci cations 21 Packing li...

Page 3: ...cture Refrigerant Tubing CAUTION Risk Of Fire Or Explosion Flammable Refrigerant Used Consult Repair Manual Owner s Guide Before Attempting To Install Or Service This Equipment All Safety Precautions...

Page 4: ...ondenser fan and evaporator fan with vortex e ect refrigeration is adopted with stable lasting performance and low noise Ensures that the temperature in the cabinet is more uniform and stable and the...

Page 5: ...ing matters highlighted in warning signs may cause serious casualties or damages to the pharmacy refrigerator and related property losses Behavior or operation that must be observed Product with the s...

Page 6: ...k Please use the special power supply indicated on the nameplate of the pharmacy refrigerator otherwise it may cause re or electric shock If the voltage is lower than 187 V or higher than 242 V it is...

Page 7: ...not used for a long time unplug the power plug to prevent electric shock leakage or res caused by the aging power cord If the pharmacy refrigerator is idle for a long time in an unsupervised area mak...

Page 8: ...pharmacy refrigerator by themselves Otherwise it may cause res or personal injuries due to improper operations Do not ground the pharmacy refrigerator through gas pipe power supply pipe telephone line...

Page 9: ...ng the sharp edges or corners and injuries to personnel Hold the handle to close the door so that the door will not catch your ngers When moving pharmacy refrigerators the inclination angle should not...

Page 10: ...lug the test hole with insulating material again otherwise the temperature in the box may not reach the set temperature value and condensation will appear around the outside of the through hole Please...

Page 11: ...bient temperature tolerance is within 16 C 32 C and recommended temperature is within 18 C 25 C If necessary air conditioning system should be used Environmental humidity lower than 80 Rh Avoid heavy...

Page 12: ...ensure that the input voltage requirements in the installation environment can be met Device shall be reliably grounded If the power cord socket is equipped with grounding wire check whether the grou...

Page 13: ...be left around the pharmacy refrigerator to facilitate ventilation and heat dissipation 4 Lock the front casters and adjust the adjustable feet optional Please rotate the adjustable feet clockwise to...

Page 14: ...perature and humidity of this product are di erent from the actual temperature and humidity in the box which is a normal phenomenon Please don t place items in the space between the bottom of the inne...

Page 15: ...letely closed Initial start up Please observe the following rules when conducting initial start up 1 Under no load condition please connect the power plug to right plugboard and the plugboard should n...

Page 16: ...heel Schematic Diagram VS350 Glass door lock Refrigeration air duct Refrigeration fan Glass door body Due to the improvement of the product and di erent models the actual product may be di erent from...

Page 17: ...ing the display board ashes at an interval of 1 second to display the set temperature value When a fault occurs the display board will display the fault code and if there are multiple faults the fault...

Page 18: ...ard shows the temperature in the Pharmacy refrigerator chamber In the case of unlocking 1 Press and hold the SET key for 3s and the digital tube ashes 1s inter val and displays the SEt parameter numbe...

Page 19: ...tment Note The lighting function is independent and is not a ected by key lock and temperature sensor fault User parameter table Parameter number Description Scope Note Default 5 0 C Default 3 0 Set t...

Page 20: ...t code and the buzzer will beep at an interval of 1 second Press any key to mute but the fault code will not disappear until the fault is removed The fault code and description are shown in the follow...

Page 21: ...gs can keep the pharmacy refrigerator fresh Use a dry cloth to wipe o a small amount of dust outside and inside of the pharmacy refrigerator as well as that on all accessories If the pharmacy refriger...

Page 22: ...quali ed professional recycling organizations for scrapping and disposal in accordance with local regulations and ordinances non professionals should not disassemble or decompose the device without a...

Page 23: ...ns 220 240V 50Hz 190W 1 0A MC 5L316B dB 316L VS350 Packing list The warranty card and certi cate are included in the instruction and the speci c packing list shall prevail in accordance with the real...

Page 24: ...Electrical schematic diagram Electrical schematic diagram of VS350 22...

Page 25: ......

Reviews: