V2 PD9 Manual Download Page 5

18

CONTROL PANEL

Per form the electrical connections to the terminal
board, then supply power to the system: the unit will
check the operation status of the display, by turning all
the segments on for 1,5 seconds (

8.8.8.8

); after this,

the display will show the firmware version for 1,5
seconds, for instance 

Pr 1.0

.

Now, the display will show a control panel:

The control panel represents the physical status of the 
terminal board contacts and of the program mode keys:
if the upper ver tical segment is on, the contact is clo-
sed; if the lower ver tical segment is on, the contact is
open (the above picture shows an instance where the
inputs START, START P, PHOTO1, PHOTO2, and STOP
have all been correctly connected).

PROGRAMMING

The PD9 unit presents a programming structure with
menus, each of which corresponds to a function in the
unit (function menu) or to a working time setting (time
menu). 
Time menus allow adjusting the unit working times
(e.g.: leaf opening or closing time, locking time, preflas-
hing time, etc.).

Time programming will be carried out through an algo-
rithm, which speeds up the operations by automatically
matching the adjustment pitch according to the current
set up value:

from 0 seconds to 1 minute the adjustment pitch is

equal to 0,5 second:

from 1 minute to 10 minutes the adjustment pitch

is equal to 5 seconds:

for more than 10 minutes the adjustment pitch is

equal to 30 seconds:

On the other side, the function menu are used to acti-
vate the required functions (e.g. timed lights, PHOTO1
active as a travelling edge, PHOTO2 inactive, etc.).

Some time menus depend on cer tain function menus
(e.g.: if the AUTOMATIC CLOSING is activated – but only
in this case – a TIME-OUT need to be set); then, to sim-
plify the programming, these time menus have been
placed in the function menus on which they depend.
Specifically, menus AUTOMATIC CLOSING (Ch.AU) and 
PHOTOCELL TIME-OUT (Ft.PA) offer some “time menus”
among the selectable options.

FUNCTION OF KEYS
MENU, UP, DOWN

To activate the program mode, proceed as follows. 

After powering the unit, the display should show the 
control panel (therefore, check that the connections
made are correct).

Press and hold key MENU until the display 
shows 

dEF

.

Now your programming has been activated.
WARNING: in case no operation is carried out for more
than one minute, the gearcase exits from the program-
ming mode without saving any of your setups and chan-
ges, which will get lost. 
You will have to exit from the programming mode –
through the 

FinE

menu – to store all set up data (even

in case you choose the default data).

When the program mode function is activated, press
key UP or DOWN to select the menus, thus per forming
a for ward or backward shift (for a fast shift, press and
hold). 

Press key MENU to access the settings in order to
change them through keys UP and DOWN.

Pressing the UP key, the menu functions can be 
scrolled from below.

Pressing the DOWN key, the menu functions can be 
scrolled from above.

Pressing the MENU key, the settings to be changed 
can be accessed and selected by pressing again.

ATTENTION:

when the program mode function is not 

activated, pressing of the UP key corresponds to the
START command, pressing of the DOWN key corre-
sponds to the PEDESTRIAN START command: this way,
the ser vice engineer is enabled to per form the test and
the set-up.

The PD9 unit can be set up in two different program
modes: DEFAULT PROGRAM MODE or CUSTOM 
PROGRAM MODE.

In the following pages you can find a functions diagram
with information concerning PD9. 

For the use of the function char t proceed as follow:

Press DOWN key to flow the char t from the top to 
the bottom. The functions 

dEF

t.AP1

t.AP2

etc. 

will be appear.

Summary of Contents for PD9

Page 1: ...ND DOUBLE SWING GATES I GB GATESTORE Ltd 682 Anlaby High Rd Kingston Upon Hull HU3 6UZ tel 0845 226 3123 fax 01482 505001 info gatestore co uk www vidue co uk COMPANY WITH QUALITY SYSTEM CERTIFIED BY QMSI UNI EN ISO9001 IL n 155 EDIZ 05 05 03 ...

Page 2: ...TRIAN GATE 20 CLOSING TIME GATE 1 20 CLOSING TIME GATE 2 20 CLOSING OF PEDESTRIAN GATE 20 GATE DELAY DURING OPENING 20 GATE DELAY DURING CLOSING 21 LOCK TIME 21 BACKLASH TIME 21 PRE FLASHING TIME 21 MOTOR POWER 1 21 MOTOR POWER 2 21 START SLOWING DOWN 21 END OF STROKE SLOWING DOWN 21 START IN OPENING 22 START IN CLOSING 22 START IN PAUSE 22 PEDESTRIAN START IN OPENING 22 THE PHOTOCELL IN PAUSE 22 ...

Page 3: ...evel Installation requires mechanical and electrical skills therefore it shall be carried out by qualified personnel only who can issue the Compliance Certificate concerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the following rules EN 12453 EN 12445 EN 12978 as well as any local rule in force Also the automation upstream elect...

Page 4: ...4 channels and each of them is suitable for a command of PD9 control unit CHANNEL 1 START CHANNEL 2 PEDESTRIAN START CHANNEL 3 STOP CHANNEL 4 COURTESY LIGHTS Before programming 4 channels and function logics read carefully the instructions of MR1 WARNING we suggest to use the external aerial model ANS433 in order to guarantee the maximal range TERMINAL CONNECTION Antenna Antenna shield Opening con...

Page 5: ...ng these time menus have been placed in the function menus on which they depend Specifically menus AUTOMATIC CLOSING Ch AU and PHOTOCELL TIME OUT Ft PA offer some time menus among the selectable options FUNCTION OF KEYS MENU UP DOWN To activate the program mode proceed as follows After powering the unit the display should show the control panel therefore check that the connections made are correct...

Page 6: ...ckout function is required a no maintenan ce lead accumulator needs to be connected by means of special coupling terminals by strictly complying with the silk screen printing polarities of the control card The accumulator shall have the following characteristics TYPE lead and with no maintenance need VOLTAGE 12 VOLT CAPACITY 4 2 Ah Position the battery according to the figure and use the areas ind...

Page 7: ... menu is adjustable from 0 to 2 minutes and determines the time of opening of gate 2 WARNING if it is a one door gate such time shall be set up on 0 OPENING TIME OF PEDESTRIAN GATE This menu is adjustable from 0 seconds to t AP1 and determines the opening time of pedestrian gate CLOSING TIME GATE 1 This menu is adjustable from 0 to 2 minutes which is the closing time for gate 1 To avoid the uncomp...

Page 8: ... or in closing phase the time of pre flashing can be adjusted from 0 to 2 minutes END OF STROKE SLOWING DOWN Such a menu allows enabling the door slowing down at their end of stroke by means of two speeds which can be set up according to your needs vEL1 corresponds to 25 of power vEL2 corresponds to 50 of power MOTOR 1 POWER Such a menu enables the sensitivity adjusting of the motor 1 current sens...

Page 9: ...g has been activated menu Ch AU PEDESTRIAN START IN OPENING This menu permits to select the functions of the command of START P during the opening phase PAUS the command PEDESTRIAN START stops the gate and goes in pause ChiU the command PEDESTRIAN START closes the gate no the command PEDESTRIAN START is not available THE PHOTOCELL IN PAUSE This menu permits to determine the functioning of two phot...

Page 10: ... is also possible to control this connection using the code memorized in the radio input tEL4 in this last case the con nection courtesy light becomes an auxiliary connection to which it is possible to match one of the following functional logics monostable it activates the output relay through all the tx transmission time when the transmission ends the relay is disconnected bistable it activates ...

Page 11: ...he connection of the photocell TIMER FUNCTION This function permits to program the time bands of opening and closing It is necessary to connect a 24h timer with a contact normally open in parallel with the START or PEDE STRIAN START input When the timer contact is closed the gate gets into opening phase and remains opened until the contact of the timer opens causing the re closing of the gate IMPO...

Page 12: ...ATA HAVE BEEN MEMORIZED THE CONTROL UNIT IS READY TO BE USED COUNTER VIEWING Such a menu allows viewing the number of opera tion cycles which such automatism carries out and it also enables the final user to set up a limit value in order to show him when the actuators service is required tot Total number of completed cycles the display views in thousands press DOWN to view units SErv number of cyc...

Page 13: ...lock operation time Lock is not energized it corresponds to 0 Backlash time Disabled recoil it corresponds to 0 Pre flashing time Disabled pre blink it corresponds to 0 Under stress motor 1 alarm threshold it deals with a conventional number Under stress motor 2 alarm threshold it deals with a conventional number Start slowing down End of stroke slowing down Motor slowing down at speed 1 Disabled ...

Page 14: ...OP input not available STOP command stops the gate pressing the START command gate continues the motion STOP command stops the gate START command starts moving in the opposite direction PHOTO 1 input Not available Input is available for the connection of the rib Input is available for the connection of the photocell PHOTO 2 input Photocell is active in closing and also when the gate is still Not a...

Page 15: ...28 NOTE ...

Reviews: