17
Other characteristics:
•
Self-secured power against shor t circuits inside the
gearcase, on motors and relevant connected
accessories.
•
Power adjustment by means of current shutting
(PWM: Power motor controller).
•
Obstacle detection by means of monitoring the
motor absorbed current.
•
Operation without the network voltage by means of
buffer batter y (optional).
•
Warning light showing the status of the gate.
•
Programmable logic auxiliar y relay for cour tesy
lights or other use.
PD9 gearcase has been prearranged for the coupling of
a Personal Pass MR1 receiver having a high-sensitivity
super-heterodyne architecture.
ATTENTION: it is necessary to turn off the
control unit power before doing the operations
mentioned here below. Please pay attention to
the way you connect the removable modules.
PLUGGING THE MR1 RECEIVER
MODULE IN
MR1 module receiver is provided with 4 channels and
each of them is suitable for a command of PD9 control
unit:
CHANNEL 1
START
CHANNEL 2
PEDESTRIAN
START
CHANNEL 3
STOP
CHANNEL 4
COURTESY LIGHTS
Before programming 4 channels and function
logics read carefully the instructions of MR1.
WARNING
: we suggest to use the external aerial
(model:
ANS433
) in order to guarantee the maximal
range.
TERMINAL CONNECTION
Antenna
Antenna shield
Opening control for the connec-
tion of control devices with
normally open contact
Opening controls for pedestrian
access for the connection of
control devices with normally
open contact
Common (-)
STOP command
Normally closed contact
Photocell 1
Normally closed contact
Photocell 2
Normally closed contact
Common (-)
Power 12VDC for photo-
cells and other accessories
Electric lock 12VAC
Warning light 24VAC 3W
Power output 24VDC
for motor 2
Power output 24VDC
for motor 1
Backup batter y 12VDC
Cour tesy light 230 VAC 10 W
Flashing light 230 VAC 40 W
Neutral 230VAC
Phase 230VAC
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.-12.
13.-14.
15.-16.
17.-18.
19.-20.
21.-22.
23.- 24.
25.
26.
BUTTON
P1
LED
L1
Summary of Contents for PD9