23
AUTOMATIC CLOSING
Permits the selection between the semiautomatic or automatic functio-
ning. By the semiautomatic functioning the command of START or PEDE-
STRIAN START opens the gate, when the opening is complete the gate
remains still until the successive command of opening, which will reclose
it. On the other hand, it stops automatically and remains in pause phase
for the set time (t.PAU), then it closes again through the set closing time.
no
the automatic reclosing is not available, the gate is semiautomatic.
t.PAU
the reclosing is available, the standstill time is set from 0 to 999.
IMPORTANT
: If the automatic reclosing is not available, is necessar y to
enable the star t command in pause(menu St.PA)
COURTESY LIGHTS
Thanks to the connection "cour tesy light" the
PD9 control unit enables the connection of the
cour tesy lights (I.E. garden lights), which can
work automatically (lights on for the whole cycle)
or timed (lights on for a time adjustable from 0 to
999 seconds). The lights turn on with a START or
PEDESTRIAN START control. It is also possible to
control this connection using the code memorized
in the radio input tEL4, in this last case the con-
nection "cour tesy light" becomes an auxiliar y connection to which it is possible to match one of the
following functional logics:
monostable
:
it activates the output relay through all the tx transmission time, when the
transmission ends the relay is disconnected.
bistable
:
it activates the relay with the tx first transmission, the relay disconnects with the
second transmission.
timer
:
the tx transmission triggers the relay which disconnects automatically after a time
adjustable between 0 and 999 seconds.
t.LUC
Cour tesy lights switch on when the gate moves and when it stops they stay switched on for
a time which can be set up from 0 to 20 minutes.
CiCL
the cour tesy lights are on through the whole cycle.
AUS
auxiliar y exit with adjustable logical functioning.
If the function selected is AUS, one of the following will appear on the display:
tiM
timed auxiliar y exit (time adjustable from 0 to 999 seconds)
biSt
auxiliar y output relay with bistable functioning
Mon
auxiliar y output relay with monostable functioning
FLASHLIGHT IN PAUSE
This menu permits to activate or to disable the flashlight
during the pause time.