V2 PD9 Manual Download Page 12

25

PHOTO 2 INPUT 

The photocell 2 is active in closing: if it is dimmed during the 
closing it stops the gate and inver ts the motion. The option CFCh
activates the photocell even when the gate is still: closed gate
means that no impulse has been given, either it is in pause or it has
received a STOP command. In this case through all the time of the
darkening of the photocell the control unit does not receive any com-
mand of activation at any opening / closing cycle.

CFCh

the input PHOTO 2 is available: the photocell is active in 
closing and also when the gate is still

no

the input PHOTO 2 is not available

Ch

the input PHOTO 2 is available: the photocell is active 
only during the closing

END OF PROGRAMMING

This menu allows to finish the programming (both default and 
personalized) saving the modified data into memor y.

no

fur ther corrections to carr y out: do not quit the 
programming

Si

end of programming

THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL
UNIT IS READY TO BE USED.

COUNTER VIEWING

Such a menu allows viewing the number of opera-
tion cycles which such automatism carries out and
it also enables the final user to set up a limit
value in order to show him when the actuators
ser vice is required.

tot

.

Total number of completed cycles (the 
display views in thousands, press DOWN 
to view units).

SErv

number of cycles before the next request 
for ser vice. 

Such a function is disabled by default, by pressing
UP the display will view -01.0, which shows a
1000-cycle countdown after which PD9 will show
the final user that a ser vice is required. Such a
number has been rounded off to hundreds and it
can be set up on 1000-step; set up the desired
value, and then press MENU to confirm.

The request for a ser vice will be signalled by means of double blinks
during the whole operation cycle.

WARNING

: only a qualified staff shall carr y out all ser vice operations.

Once the ser vice has been carried out, the relevant ser vice menu

SErv

shall be set up again. 

PD9 will continue signalling the request for a ser vice until such para-
meter is not set up.

Summary of Contents for PD9

Page 1: ...ND DOUBLE SWING GATES I GB GATESTORE Ltd 682 Anlaby High Rd Kingston Upon Hull HU3 6UZ tel 0845 226 3123 fax 01482 505001 info gatestore co uk www vidue co uk COMPANY WITH QUALITY SYSTEM CERTIFIED BY QMSI UNI EN ISO9001 IL n 155 EDIZ 05 05 03 ...

Page 2: ...TRIAN GATE 20 CLOSING TIME GATE 1 20 CLOSING TIME GATE 2 20 CLOSING OF PEDESTRIAN GATE 20 GATE DELAY DURING OPENING 20 GATE DELAY DURING CLOSING 21 LOCK TIME 21 BACKLASH TIME 21 PRE FLASHING TIME 21 MOTOR POWER 1 21 MOTOR POWER 2 21 START SLOWING DOWN 21 END OF STROKE SLOWING DOWN 21 START IN OPENING 22 START IN CLOSING 22 START IN PAUSE 22 PEDESTRIAN START IN OPENING 22 THE PHOTOCELL IN PAUSE 22 ...

Page 3: ...evel Installation requires mechanical and electrical skills therefore it shall be carried out by qualified personnel only who can issue the Compliance Certificate concerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the following rules EN 12453 EN 12445 EN 12978 as well as any local rule in force Also the automation upstream elect...

Page 4: ...4 channels and each of them is suitable for a command of PD9 control unit CHANNEL 1 START CHANNEL 2 PEDESTRIAN START CHANNEL 3 STOP CHANNEL 4 COURTESY LIGHTS Before programming 4 channels and function logics read carefully the instructions of MR1 WARNING we suggest to use the external aerial model ANS433 in order to guarantee the maximal range TERMINAL CONNECTION Antenna Antenna shield Opening con...

Page 5: ...ng these time menus have been placed in the function menus on which they depend Specifically menus AUTOMATIC CLOSING Ch AU and PHOTOCELL TIME OUT Ft PA offer some time menus among the selectable options FUNCTION OF KEYS MENU UP DOWN To activate the program mode proceed as follows After powering the unit the display should show the control panel therefore check that the connections made are correct...

Page 6: ...ckout function is required a no maintenan ce lead accumulator needs to be connected by means of special coupling terminals by strictly complying with the silk screen printing polarities of the control card The accumulator shall have the following characteristics TYPE lead and with no maintenance need VOLTAGE 12 VOLT CAPACITY 4 2 Ah Position the battery according to the figure and use the areas ind...

Page 7: ... menu is adjustable from 0 to 2 minutes and determines the time of opening of gate 2 WARNING if it is a one door gate such time shall be set up on 0 OPENING TIME OF PEDESTRIAN GATE This menu is adjustable from 0 seconds to t AP1 and determines the opening time of pedestrian gate CLOSING TIME GATE 1 This menu is adjustable from 0 to 2 minutes which is the closing time for gate 1 To avoid the uncomp...

Page 8: ... or in closing phase the time of pre flashing can be adjusted from 0 to 2 minutes END OF STROKE SLOWING DOWN Such a menu allows enabling the door slowing down at their end of stroke by means of two speeds which can be set up according to your needs vEL1 corresponds to 25 of power vEL2 corresponds to 50 of power MOTOR 1 POWER Such a menu enables the sensitivity adjusting of the motor 1 current sens...

Page 9: ...g has been activated menu Ch AU PEDESTRIAN START IN OPENING This menu permits to select the functions of the command of START P during the opening phase PAUS the command PEDESTRIAN START stops the gate and goes in pause ChiU the command PEDESTRIAN START closes the gate no the command PEDESTRIAN START is not available THE PHOTOCELL IN PAUSE This menu permits to determine the functioning of two phot...

Page 10: ... is also possible to control this connection using the code memorized in the radio input tEL4 in this last case the con nection courtesy light becomes an auxiliary connection to which it is possible to match one of the following functional logics monostable it activates the output relay through all the tx transmission time when the transmission ends the relay is disconnected bistable it activates ...

Page 11: ...he connection of the photocell TIMER FUNCTION This function permits to program the time bands of opening and closing It is necessary to connect a 24h timer with a contact normally open in parallel with the START or PEDE STRIAN START input When the timer contact is closed the gate gets into opening phase and remains opened until the contact of the timer opens causing the re closing of the gate IMPO...

Page 12: ...ATA HAVE BEEN MEMORIZED THE CONTROL UNIT IS READY TO BE USED COUNTER VIEWING Such a menu allows viewing the number of opera tion cycles which such automatism carries out and it also enables the final user to set up a limit value in order to show him when the actuators service is required tot Total number of completed cycles the display views in thousands press DOWN to view units SErv number of cyc...

Page 13: ...lock operation time Lock is not energized it corresponds to 0 Backlash time Disabled recoil it corresponds to 0 Pre flashing time Disabled pre blink it corresponds to 0 Under stress motor 1 alarm threshold it deals with a conventional number Under stress motor 2 alarm threshold it deals with a conventional number Start slowing down End of stroke slowing down Motor slowing down at speed 1 Disabled ...

Page 14: ...OP input not available STOP command stops the gate pressing the START command gate continues the motion STOP command stops the gate START command starts moving in the opposite direction PHOTO 1 input Not available Input is available for the connection of the rib Input is available for the connection of the photocell PHOTO 2 input Photocell is active in closing and also when the gate is still Not a...

Page 15: ...28 NOTE ...

Reviews: