PD9 FUNCTION TABLE
DISPLAY
Ch.AU
LUCi
LP.PA
In.LP
OroL
StoP
Fot 1
Fot 2
Cont
Fine
DATA
no
0.5" ÷ 20'
t.LUC
CiCL
AUS
tiM
Mon
biSt
no/Si
no/Si
no/Si
no
ProS
invE
no
CoSt
APCh
CFCh
no
Ch
tot.
Man
no
Si
DESCRIPTION
Automatic closing
- The automatic closing is not active (it corresponds to 0)
- The gate closes after the setup time)
Cour tesy Light
- Lights star t time adjustable from 0 to 20 min.
- Lights are on trough the whole cycle
- Auxiliar y output
- Timed aux out (from 0 to 20 min.)
- Aux out relay with bistable functioning
- Aux out relay with monostable functioning
Flashlight in pause
Flashlight with intermittence
Timer function
STOP input
- STOP input not available
- STOP command stops the gate: pressing the START command gate
continues the motion
- STOP command stops the gate: START command star ts moving in
the opposite direction
PHOTO 1 input
- Not available
- Input is available for the connection of the rib
- Input is available for the connection of the photocell
PHOTO 2 input
- Photocell is active in closing and also when the gate is still
- Not available
- Photocell is active during the closing
Counter viewing
- Total number of completed cycles (the display views in thousands
or in units)
- Number of cycles before the next request for ser vice (such a
number has been rounded off to hundreds and it can be set up
on 1000-step; in case it is set up on 0, the request will be
disabled and
no
will be viewed)
End of programming
- It does not exit from the program menu
- It exits from the program menu by storing the setup parameters
MEMO
DATA