PARAMETER
VALUE
SUBMENU DESCRIPTION
DEFAULT
CHAPTER
MEMO
FT.TE
0.1”-2.0”
Photocell test enable
NO
11.1
NO
Function disabled
COS1
Safety ribbon 1 mode
NO
12.2
NO
No function
APCH
Enabled opening and closing
AP
Enabled opening
COS2
Safety ribbon 2 mode
NO
12.2
NO
No function
APCH
Enabled closing and opening
CH
Enabled closing
CO.TE
Ribbon type and test
NO
12.2
NO
Mechanic - no test
RESI
Resistive
FOTO
Optical with test
CH.OS
Closure after obstacle
MAN
12
MAN
Manual
AUTO
Automatic (if activated through CH.AU
parameter)
I.ADI
ADI device enable
NO
21
NO
ADI interface disabled
SI
ADI interface enabled
RICH
Reclosing at startup
SI
NO
Function disabled
SI
When the power supply is activated the unit
set for closing: the first START command starts
the motor closing. If the automatic closing is
activated (CH.AU), the count of pause time
starts and closing is activated
T.ADD
0.5”-1’
Extra travel
If in some cases the gate does not reach the
position needed to activate the limit switch,
you can set an additional time by configuring
the parameter
T.ADD
: if the limit switches is
not activated the gate continues its movement
up to the end of the set time
1.0”
NO
The gate ends its travel even if the limit
switches have not been activated
FINE
Exit the programming menu
NO
NO
Do not exit the programming menu
SI
Exits the programming menu by storing the
parameters set