ENGLISH
- 37 -
3 - INSTALLATION OF THE MOTOR
3.1 - POSITIONING OF THE MOTOR
To fix HYPERFOR, follow the instructions below:
1.
use the measurements indicated in the drawing for the
foundations
2.
Arrange for one or two pipes for the passage of electric cables
3.
Assemble the 4 clamps on the anchoring plate and fix them
with the 4 bolts issued with the motor
4.
Pour the concrete and position the anchoring plate
m
WARNING: check that the plate be on a perfectly
levelled surface and parallel to the gate
5.
Wait for the complete setting of the concrete
6.
Unscrew the bolts fixing the base to the clamps and put the
motor on the plate
7.
Adjust the 4 grains
F
to make the motor be perfectly levelled
8.
Control that the motor is perfectly parallel to the gate, then
insert the 4 washers
R
and lightly screw the 4 bolts
D
50 mm
323 mm
20 mm
565 mm
10cm
30cm
10cm
F
R
D