ENGLISH
DISPLAY
DATA
DESCRIPTION
DEFAULT
MEMO
DATA
AUS
Auxiliary channel
tiM
- Time working
1’00
biSt
- Bistable working
Mon
- Monostable working
LP.PA
no/Si
Flashlight in pause
no
St.rt
Operation modes
StAn
StAn
- Start inputs from terminal board are disabled
no
- Standard operation
AP.CH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
StoP
STOP input
no
no
- STOP input not available
invE
- STOP command stops the gate: START command starts moving in the opposite direction
ProS
- STOP command stops the gate: pressing the START command gate continues the motion
Fot 1
PHOTO 1 input
no
APCh
- Input is available for the connection of the photocell
no
- Not available
Fot 2
PHOTO 2 input
CFCh
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
Ft.tE
no/Si
Test of operating of the photocells:
no
CoS1
Input safety edge 1 (fix edge)
no
no
- Non-active input
AP
- Input active only in opening
APCH
- Input active both in opening and closure
CoS2
Input safety edge 2 (mobile edge)
no
no
- Non-active input
CH
- Input active only in closure
APCH
- Input active both in opening and closure
Co.tE
Test of operating of the safety edges:
no
no
- Test disabled
Foto
- Test enabled for optical type safety edges
rESi
- Test enabled for resistive rubber safety edges
W.L.
- Test enabled for wireless edge system
FC.En
no/Si
End of stroke inputs
Si
EnCo
no/Si
Encoder Input
no
S.EnC
0 ÷ 7
Encoder sensitivity
0
i.Adi
no/Si
Enabling the ADI device
no
ASM
0.5” ÷ 1.0’
Anti-skid function
1.0”
no
- Function disabled
FinE
End of programming
no
no
- It does not exit from the program menu
Si
- It exits from the program menu by storing the setup parameters
PD18 FUNCTION TABLE