background image

en-1

CARTON CONTENTS ART200K

Drive motors

2x

Release key

2x

Box for control

1x

Cover for box

1x

Hinges for box

4x

Control

1x

Transformer

1x

Baseplate For Transformer

1x

Remote control

1-2x*

Radio receiver

1

Radio module

1x

Hardwarebag For Box

1x

Pillar fittings

2x

Gate fittings

2x

Door arm

2x

Hardwarebag 

1x

Instructions

1x

Flashing light

1x

Key switch

1x

Photocells

1x

* depending on model resp. available as optional accessory

INSTALLATION CHECKLIST - PREPARATIONS

Check the carton contents and read the instructions carefully. Make sure your gate equipment operates perfectly. The gate must run evenly and

smoothly and must not stick at any point. Remember that the ground level may be several centimeters higher in winter. The gate must be stable

and as free of backlash in order to prevent any unwanted movement. The easier the gate movement the less power is needed by the motor.
Write down any materials you still need and obtain them before starting to install. Heavy-duty plugs, bolts, gate stops, cables, distribution boxes,

tools, etc.

PLEASE START BY READING THESE IMPORTANT SAFETY RULES • SAVE THESE INSTRUCTIONS

This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or

damage to property. Please read these warnings carefully.
This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in

strict accordance with the following safety rules.

Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or property

damage.

Installation and wiring must be in compliance with

your local building and electrical installation codes.

Power cables must only be connected to a properly

earthed supply.

Any entrapment possibility by the moving wing

between wing & walls must be secured with safety

edges or IR-sensors.

Disconnect electric power to the system before making

repairs or removing covers.

A disconnecting device must be provided in the

permanently-wired installation to guarantee  all-pole

disconnection by means of a switch (at least 3mm

contact gap) or by a separate fuse.

When using tools and small parts to install or carry

out repair work on a gate exercise caution and do not

wear rings, watches or loose clothing.

Make sure that people who install, maintain or operate

the gate drive and/or the control board are qualified and

follow these instructions. 

Keep these instructions in a safe place so that you can

refer to them quickly when you need to.

Please remove any locks fitted to the gate in order to

prevent damage to the gate.

Frequently examine the installation for imbalance and

signs of wear or damage to cables, hardware and

mountings. Do not use if repair or adjustment is

necessary. Gates which stick or jam must be repaired

immediately. 

Employ a qualified technician to repair the

gate, never attempt to repair it yourself.
Keep additional accessories away from children. Do not

allow children to play with pushbuttons or remote controls.

A gate can cause serious injuries as it closes.

After the installation a final test of the full function of

the system and the full function of the safety devices

must be done.

The full protection against potential squeeze or

entrapment must work direct when the drive arms are

installed.

This drive cannot be used with a gate incorporating a

wicket door unless the drive cannot be operated with

the wicket door open.

IMPORTANT FITTING AND OPERATING INSTRUCTIONS

WARNING / ATTENTION

Intelligent Security & Fire Ltd.

Summary of Contents for ART200K

Page 1: ...lectrical installation codes Power cables must only be connected to a properly earthed supply Any entrapment possibility by the moving wing between wing walls must be secured with safety edges or IR s...

Page 2: ...again Outside temperature and gate represent important parameters for actual operating duration AVAILABLE INSTALLATION ACCESSORIES 1 041ASWG 0482 50 50m roll of installation cable 6 pole for outdoor u...

Page 3: ...einforced additionally as they do not withstand the strain otherwise GATE CONFIGURATION The ART is suitable for use with wide pillars up to about 30cm in width The amount of room around the pier affec...

Page 4: ...side and inside of the gate in order to prevent wood from giving and the connection to become loose Thin wooden gates without metal frame must be reinforced additionally as they do not withstand the s...

Page 5: ...x 45 switch fully pushed cam operates switch Gate open switch free 4 TYPICAL CONFIGURATION OF A UNIT 1 Motor 2 Control board 3 Photocell active for closing max height 200 mm First photocell 4 photocel...

Page 6: ...uired distances and establishing correct position of drill holes Hardware not included B Fasten baseplate for transformer in casing Screws 3 5 x 9 5mm C Fasten transformer on to baseplate do this usin...

Page 7: ...ROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wire to base plate with washer and nut exactly as shown in p...

Page 8: ...for a battery kit 475E 041ADBL 0115 Motor MASTER motor 1 master opens first Motor SECOND motor 2 Second opens second 24V 150mA Flashing light accessory MASTER Motor1 BRN brown cable GRN green cable WH...

Page 9: ...n failsafe photocell must be installed The Chamberlain failsafe system 2 cable system has small LEDs light that can be seen from the outside on both sides to indicate the status of the photocell Diagn...

Page 10: ...gate may work improperly Redo programming if required DELETE Press learn buttons CH1 or CH2 for approx 10 seconds until LED goes out All codes programmed to this channel are deleted 1 2 Motor 1 or 2 m...

Page 11: ...for approx 2 3 seconds until yellow LED flashes 2 Monitor the gate Press and hold P1 for 1 2 seconds The wing with motor 1 opens If motor 1 closes it is wired incorrectly and the red and blue wires of...

Page 12: ...re possible Activate 1 Press and hold P2 until yellow LED starts flashing 2 Now count the time you wish to program 3 Press P2 again Done Deactivate 1 Press and hold P2 until yellow LED starts flashing...

Page 13: ...if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocells 1 block installation A Objec...

Page 14: ...not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not...