TECHNICAL DATA OF MOTOR CONTROL:

Voltage

230VAC

Transformer

230/24VAC minimum60VA

Output motor

24VDC max.

Supply accessories

24VDC - 100mA

Operating temperature

-20°C - +55°C

Degree of protection

IP54

30VDC

MOTOR

MASTER

+

-

MOTOR

SECOND

24V/150mA BRN  GRN  WHT  YEL

MASTER

BRN  GRN  WHT  YEL

SECOND

COM PHOTO

1        2

COM STOP/*

8.2

Ω

 

DIAGNOSTIC

LEARN

PHO1

PHO2

STOP/8.2K

JP2

JP1

OPEN / PED

1/2 MOTOR

STOP/8.2K

P1

P2

P3

L

N

250V/2A

250V/2A

TRANSFORMER

230VAC

INPUT

24VAC

RADIO

801719

/ LAMP

Ω

 

8.2

+

+ -

RED

RED

BLUE

BLUE

           230VAC

+

+

+

Ω

 

+

PE

PE

WIRING OF CONTROL / SUMMARY

a) start with still dead 230Volts supply cable on the left side of the box.

b) Attach cable eye to ground wire. Then connect ground wire to base 

plate with washer and nut (exactly as shown in picture detail).

Connect all other cables to control.

Attention:

Check repeatedly that cable colours are connected correctly

to motor. Otherwise motor might be damaged or will not operate

properly. Pay special attention when using distribution boxes.

We recommend the following accessories:

LA400-JB40E Kit for

cable extension of one installation unit. Consists of 12m of 

cable 6-pole with identical colours, distribution box IP65,cable screw

joints and fastening material

Intelligent Security & Fire Ltd.

Summary of Contents for ART200K

Page 1: ...lectrical installation codes Power cables must only be connected to a properly earthed supply Any entrapment possibility by the moving wing between wing walls must be secured with safety edges or IR s...

Page 2: ...again Outside temperature and gate represent important parameters for actual operating duration AVAILABLE INSTALLATION ACCESSORIES 1 041ASWG 0482 50 50m roll of installation cable 6 pole for outdoor u...

Page 3: ...einforced additionally as they do not withstand the strain otherwise GATE CONFIGURATION The ART is suitable for use with wide pillars up to about 30cm in width The amount of room around the pier affec...

Page 4: ...side and inside of the gate in order to prevent wood from giving and the connection to become loose Thin wooden gates without metal frame must be reinforced additionally as they do not withstand the s...

Page 5: ...x 45 switch fully pushed cam operates switch Gate open switch free 4 TYPICAL CONFIGURATION OF A UNIT 1 Motor 2 Control board 3 Photocell active for closing max height 200 mm First photocell 4 photocel...

Page 6: ...uired distances and establishing correct position of drill holes Hardware not included B Fasten baseplate for transformer in casing Screws 3 5 x 9 5mm C Fasten transformer on to baseplate do this usin...

Page 7: ...ROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wire to base plate with washer and nut exactly as shown in p...

Page 8: ...for a battery kit 475E 041ADBL 0115 Motor MASTER motor 1 master opens first Motor SECOND motor 2 Second opens second 24V 150mA Flashing light accessory MASTER Motor1 BRN brown cable GRN green cable WH...

Page 9: ...n failsafe photocell must be installed The Chamberlain failsafe system 2 cable system has small LEDs light that can be seen from the outside on both sides to indicate the status of the photocell Diagn...

Page 10: ...gate may work improperly Redo programming if required DELETE Press learn buttons CH1 or CH2 for approx 10 seconds until LED goes out All codes programmed to this channel are deleted 1 2 Motor 1 or 2 m...

Page 11: ...for approx 2 3 seconds until yellow LED flashes 2 Monitor the gate Press and hold P1 for 1 2 seconds The wing with motor 1 opens If motor 1 closes it is wired incorrectly and the red and blue wires of...

Page 12: ...re possible Activate 1 Press and hold P2 until yellow LED starts flashing 2 Now count the time you wish to program 3 Press P2 again Done Deactivate 1 Press and hold P2 until yellow LED starts flashing...

Page 13: ...if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocells 1 block installation A Objec...

Page 14: ...not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not...