background image

en

-11

INITIAL OPERATION 

BASIC SETTING

Proceed step by step. If you are not sure, start again at the beginning. Take sufficient time to make these settings.

1. Are all components required for operation connected? Motors, photocells, safety contact strip, stop switch.

2. Make sure that nobody is present in the range of the gates.

3. Check/Adjustment/Correction of cams on both motors 

Gate closed:

switch free

Gate at approx. 45°:

switch fully pushed (cam operates switch)

Gate open:

switch free

(for adjustment refer to mechanical installation)

PROGRAMMING TRAVEL DISTANCES “ADVANCED”

NOTE:

In this mode P1 must be pressed 9 times. With every time the button is pressed a position (time) is stored. (This allows

programming of SOFT-STOP (slow travel) in order to adjust to application. Long or short phases of SOFT-STOP are possible.

1.

Both wings must be closed.

2.

Press P1 and P2 for approx.5-6 seconds until wing / motor 1 starts opening.Release buttons!!!

3.

Press P1 again. SOFT-STOP for wing / motor 1 in OPEN direction starts at this point.

4.

Press P1 again when OPEN position is reached.Now wing / motor 2 starts automatically to open.

5.

Press P1 again. SOFT-STOP for wing / motor 2 in OPEN direction begins at this point.

6.

Press P1 again when OPEN position is reached. Now wing / motor 2 starts closing automatically.

7.

Press P1 again. SOFT-STOP for wing / motor 2 in CLOSE direction begins at this point.

8.

Press P1 again when CLOSE position is reached. Now wing / motor 1 starts automatically to close.

9.

Press P1 again. SOFT-STOP for wing / motor 1 in CLOSE direction begins at this point.

10.

Press P1 again when CLOSE position is reached.

Done!

BASIC SETTING:

1. Press buttons P1, P2 and P3 simultaneously for approx. 2-3 seconds until yellow LED flashes.

2. Monitor the gate. Press and hold P1 for 1-2 seconds. The wing with motor 1 opens. If motor 1 closes, it is wired incorrectly and   

the red and blue wires of the motor cable must be inverted. (Caution: Disconnect Power!)

Repeat steps 1 and 2. Leave gate/s in partially open position.

NOTE:

General operation – if you release the button, the gate will immediately stop. By pressing the button again the gate will 

move in the opposite direction until you release the button, and so on.

3. Press and hold P2 for 1-2 seconds. The wing with motor 2 must open. (Do not open gate completely, only short distances.)

If motor 2 closes, it is wired incorrectly and the red and blue wires of the motor cable must be inverted. 

(Caution: Disconnect Power!)

Repeat steps 1 and 2. Leave gate/s in partially open position.

NOTE:

The control board is active for this manual setting mode for approx. 20 seconds. If necessary, start again by pressing P1, 

P2 and P3 simultaneously.

Now check the following:

1. If both operators connected open both wings completely.

2. Both wings must open completely. Do not open the wings too far! A gate stop in OPEN position is required. 

Caution: Gate must not come in contact with operator (i.e. when operator has been released for manual operation)

Wait until learn-LED goes out (20 seconds after a button was pressed).

PROGRAMMING TRAVEL DISTANCES “SIMPLE I”

NOTE:

only with stops in OPEN and CLOSE position

1.

Wings must be closed

2.

Press P1 until wing / motor 1 starts opening (learn-LED flashes resp. glows)

Automatic programming starts (slow travel)

Wing 1 moves to the stop in OPEN position

Wing 2 moves to the stop in OPEN position

Then wing 2 moves to the stop in CLOSE position.

Then wing 1 moves to the stop in CLOSE position.

When the learn-LED goes out the programming has finished.

Intelligent Security & Fire Ltd.

Summary of Contents for ART200K

Page 1: ...lectrical installation codes Power cables must only be connected to a properly earthed supply Any entrapment possibility by the moving wing between wing walls must be secured with safety edges or IR s...

Page 2: ...again Outside temperature and gate represent important parameters for actual operating duration AVAILABLE INSTALLATION ACCESSORIES 1 041ASWG 0482 50 50m roll of installation cable 6 pole for outdoor u...

Page 3: ...einforced additionally as they do not withstand the strain otherwise GATE CONFIGURATION The ART is suitable for use with wide pillars up to about 30cm in width The amount of room around the pier affec...

Page 4: ...side and inside of the gate in order to prevent wood from giving and the connection to become loose Thin wooden gates without metal frame must be reinforced additionally as they do not withstand the s...

Page 5: ...x 45 switch fully pushed cam operates switch Gate open switch free 4 TYPICAL CONFIGURATION OF A UNIT 1 Motor 2 Control board 3 Photocell active for closing max height 200 mm First photocell 4 photocel...

Page 6: ...uired distances and establishing correct position of drill holes Hardware not included B Fasten baseplate for transformer in casing Screws 3 5 x 9 5mm C Fasten transformer on to baseplate do this usin...

Page 7: ...ROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wire to base plate with washer and nut exactly as shown in p...

Page 8: ...for a battery kit 475E 041ADBL 0115 Motor MASTER motor 1 master opens first Motor SECOND motor 2 Second opens second 24V 150mA Flashing light accessory MASTER Motor1 BRN brown cable GRN green cable WH...

Page 9: ...n failsafe photocell must be installed The Chamberlain failsafe system 2 cable system has small LEDs light that can be seen from the outside on both sides to indicate the status of the photocell Diagn...

Page 10: ...gate may work improperly Redo programming if required DELETE Press learn buttons CH1 or CH2 for approx 10 seconds until LED goes out All codes programmed to this channel are deleted 1 2 Motor 1 or 2 m...

Page 11: ...for approx 2 3 seconds until yellow LED flashes 2 Monitor the gate Press and hold P1 for 1 2 seconds The wing with motor 1 opens If motor 1 closes it is wired incorrectly and the red and blue wires of...

Page 12: ...re possible Activate 1 Press and hold P2 until yellow LED starts flashing 2 Now count the time you wish to program 3 Press P2 again Done Deactivate 1 Press and hold P2 until yellow LED starts flashing...

Page 13: ...if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocells 1 block installation A Objec...

Page 14: ...not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not...

Reviews: