ENGLISH
- 44 -
EVENT CODE
DESCRIPTION
LEVEL
DISPLAY
E001
The microprocessor has been reset
0
E002
Access to the programming menu of the control unit
0
E003
Loading the DEFAULT parameters
0
E004
Self-learning of the working times
0
E015
Activating STOP
2,3,4
StoP
E019
Activating the virtual STOP (control from an ADI device)
3
i.Adi
E020
TRIAC test error
1
Err2
E032
Photocell test error detected on the FOTO input
1
Err3
E037
FOTo Photocell activation
2,3,4
Foto
E039
Activating the virtual photocell (control from an ADI device)
2,3,4
i.Adi
E041
Limit switch error on opening
1
Err4
E042
Limit switch error on closing
1
Err4
E045
Incorrect limit switch sequence
2
invE
E046
Command rejected because it was already at the limit switch
3
APEr / ChiU
E052
Strip test error detected on the COST input
1
Err5
E057
Activation of the COST safety strip
2,3,4
CoSt
E059
Activation of the virtual safety strip (control from an ADI device)
2,3,4
i.Adi
E066
Intervention of the amperometric protection on opening
2
SEnS
E067
Intervention of the amperometric protection on closing
2
SEnS
E068
Three obstacles detected on closing
2
SEnS
E080
Error during the self-learning procedure
1
Err8
E090
Attempt to access the programming menu blocked by CL1+
1
Err9
E100
Error detected on a safety device controlled by the ADI interface
1
Er10
E200
Inversion of movement caused by a command
2
Strt
E201
START command from the terminal board
4
E202
PEDESTRIAN START command from the terminal board
4
E203
START command from the ADI device
4
E209
Transmitter channel 1
4
tEL1
E210
Transmitter channel 2
4
tEL2
E211
Transmitter channel 3
4
tEL3
E212
Transmitter channel 4
4
tEL4
E240
Closing the gate as the idle time set in
t.inA
parameter has been exceeded 5
E241
Closing due to the inactivity being delayed
5
E242
Activating the ENERGY SAVING function
5