ENGLISH
- 54 -
PARAMETER
VALUE
DESCRIPTION
AntE SCor
MEMO
Ev.di
Display of the events
If this function is enabled, every time that an event changes the
normal operation of the gate (coming into action of a safety, control
by user, etc.) the display shows a message indicating the cause.
Si
Si
Si
Function activated
no
Function deactivated
Ev.M
Storage level of the events
3
3
0 - 5
The events are stored in the list of events for diagnosis according to
the set value in this menu:
0
Only the reset and the programming operations
1
Even the errors detected by the various tests (
Err2
,
Err3
, etc.).
2
Even the events that change the normal operation of the gate
(coming into action of a safety, control by user, etc.).
3
Even the safeties that have prevented the activation operation cycle
(stop, etc.).
4
Even the controls that have activated an operation cycle (start,
etc.).
5
Even the automatic actions of the unit (
En.SA
and
t.inA
)
FinE
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory.
You must exit from programming mode through this menu item if you
do not want to lose your configuration.
no
no
no
It does not exit from the program menu
Si
It exits from the program menu by storing the setup parameters