ENGLISH
- 43 -
14 - DIAGNOSTICS
(READING OF EVENT)
To perform a diagnostic on the operation of the installation,
the CITY4-EVO control unit stores events that interfere with the
normal operation of the automation.
The events are stored according to the level of importance that is
set for the
Ev.M
parameter.
Using the V2+ software (connection via USB), it is possible to
display the last 127 events.
Using the display of the control unit, it is possible to display the
last 32 events.
To access the menu follow these instructions:
1.
Press and hold down the MENU key until the
-Cnt
appears
on the display
2.
Release the MENU key: the display will show
tot
3.
Press the DOWN key twice: the display will show
EvEn
4.
Press the MENU key to display the list of events
The events are numbered in ascending order from
n-01
to
n-32
;
select the event and press the MENU key to display the following
information:
A
- EVENT CODE
The code displayed is used to define the type of event that
has occurred (see the dedicated table on the next page)
B
- STATE OF AUTOMATION
S=FE
gate stopped
S=AP
gate opening
S=PA
gate paused
S=Ch
gate closing
S=in
control unit initializing
S=M
control unit in programming phase
S=Sb
control unit on stand-by
C
- CYCLES AFTER THE EVENT
This counter displays how many cycles have been completed
after the event has occurred.
C-00
means that the event
has occurred in the current cycle which has been stopped
C-99
means 99 or more cycles were completed after the
event
D
- REPETITIONS
This counter shows how many times the event has repeated
in the same cycle (
r 0
means that the event occurred only
once)
To exit the menu, select
ESC
and press the MENU key to confirm
To delete all stored events, select
CAnC
, press the MENU key and
select
Si
to confirm
A
B
C
D