background image

ENGLISH

- 26 -

1 - IMPORTANT REMARKS

For any installation problem please contact our Customer Service 
at the 39-0172.812411 operating Monday to Friday 
from 8:30 to 12:30 and from 14:00 to 18:00.

V2 has the right to modify the product without previous 
notice; it also declines any responsibility to damage or 
injury to people or things caused by improper use or wrong 
installation.

m

 

Please read this instruction manual very carefully 

before installing and programming your control unit.

•  This instruction manual is only for qualified technicians, who 

specialize in installations and automations.

•  The contents of this instruction manual do not concern the end 

user.

•  Every programming and/or every maintenance service should 

be done only by qualified technicians.

AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE 
WITH THE EUROPEAN REGULATIONS IN FORCE:

EN 60204-1

  (Machinery safety. electrical equipment of 

          machines, part 1: general rules) 

EN 12445

    (Safe use of automated locking devices, 

     test 

methods)

EN 12453

    (Safe use of automated locking devices, 

     requirements)

•  The installer must provide for a device (es. magnetotermical 

switch) ensuring the omnipolar sectioning of the equipment 
from the power supply. The standards require a separation of 
the contacts of at least 3 mm in each pole (EN 60335-1).

•  After making connections on the terminal board, use one 

hose clamp to fix dangerous voltage wires near the terminal 
board and another hose clamp to fix safety low voltage wires 
used for accessories connection; this way, in case of accidental 
detachment of a conducting wire, dangerous voltage parts will 
not come into contact with safety low voltage ones.

•  The plastic case has an IP55 insulation; to connect flexible or 

rigid pipes, use pipefittings having the same insulation level. 

•  Installation requires mechanical and electrical skills, therefore it 

shall be carried out by qualified personnel only, who can issue 
the Compliance Certificate concerning the whole installation 
(EEC Machine Directive 89/392, Annex IIA).

•  The automated vehicular gates shall comply with the following 

rules: EN 12453, EN 12445, EN 12978 as well as any local rule 
in force. 

•  Also the automation upstream electric system shall comply with 

the laws and rules in force and be carried out workmanlike.

•  The door thrust force adjustment shall be measured by means 

of a proper tool and adjusted according to the max. limits, 
which EN 12453 allows.

•  We recommend to make use of an emergency button, to be 

installed by the automation (connected to the control unit 
STOP input) so that the gate may be immediately stopped in 
case of danger.

•  Always remember to connect the earth according to current 

standards (EN 60335-1, EN 60204-1).

2 - DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that CITY2+ products conform to the 
essential requirements established in the following directives:

•  2004/108/CEE (EMC Directive in accordance with standards  

EN 55014-1, EN 55014-2, EN 61000-3-2, 61000-3-3)

•  2006/95/CEE (Low Voltage Directive in accordance with 

standards EN 60335-1 + EN 60335-2-103)

•  99/05/CEE (Radio Directive in accordance with standard  

EN 301 489-3)

•  Directive RoHS2 2011/65/CE

Racconigi, 12/01/2010
V2 S.p.A. legal representative. 

Cosimo De Falco

3 - TECHNICAL SPECIFICATIONS

CITY2+

CITY2+L

CITY2+BC

Power supply 

230V / 50Hz 230V / 50Hz

24Vdc

Max total load

250W

200W

250W

Max load for each 
motor

150W

100W

150W

Duty clcle

40%

40%

40%

Max accessories 
load 24Vdc

7W

7W

7W

Protection fuse

2,5A

2,5A

-

Weight

3000 g

1000 g

1000 g

Dimensions

295 x 230 x 100 mm

Working 
temperature

-20 ÷ +60°C

Protection

IP55

Summary of Contents for CITY2+L

Page 1: ...BC CENTRALE DI COMANDO 24V DIGITALE PER CANCELLI AD ANTA E SCORREVOLI DIGITAL CONTROL UNIT 24V FOR LEAF SWING AND SLIDING GATES ARMOIRE DE COMMANDE NUM RIQUE 24V POUR PORTAILS VANTAILS ET COULISSANTS...

Page 2: ......

Page 3: ...ATURA 5 10 FINECORSA ED ENCODER 5 11 ANTENNA 5 12 RICEVITORE AD INNESTO 5 13 INTERFACCIA ADI 5 14 COLLEGAMENTI ELETTRICI 6 PANNELLO DI CONTROLLO 6 1 USO DEI TASTI DOWN MENU E UP PER LA PROGRAMMAZIONE...

Page 4: ...i un conduttore si evita che le parti a tensione di rete possano andare in contatto con parti a bassissima tensione di sicurezza Per la connessione di tubi rigidi e flessibili o passacavi utilizzare r...

Page 5: ...er una lampada spia o per un lampeggiante a 24V Rel ausiliario con logica programmabile per luci di cortesia lampeggiante o altro utilizzo Funzione ENERGY SAVING 5 INSTALLAZIONE L installazione della...

Page 6: ...e l uscita dei ricevitori delle fotocellule di tipo 2 tra i morsetti L8 PHOTO2 e L11 COM della centrale Usare le uscite con contatto normalmente chiuso mATTENZIONE Se vengono installate pi coppie di f...

Page 7: ...a immediatamente in blocco La direzione di azionamento del cancello al successivo comando di START o START PEDONALE dipende dal parametro STOP inverte o prosegue il moto Se l ingresso di STOP disabili...

Page 8: ...corsa di apertura del motore 2 tra i morsetti K3 FCA2 e K5 COM Collegare il finecorsa di chiusura del motore 2 tra i morsetti K4 FCC2 e K5 COM Installazione degli encoder Collegare l alimentazione di...

Page 9: ...Interface che permette il collegamento con una serie di moduli opzionali della linea V2 Fare riferimento al catalogo V2 o alla documentazione tecnica per vedere quali moduli opzionali con interfaccia...

Page 10: ...URA Z5 Motore 2 APERTURA Z6 Motore 2 CHIUSURA B1 B2 Luci di cortesia o lampeggiante 230VAC POW Alimentazione 24V fornita da alimentatore POW Alimentazione fornita da alimentatore BAT Polo del pacco ba...

Page 11: ...ITALIANO 9 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...

Page 12: ...ervento di un dispositivo di sicurezza costa o rilevatore di ostacoli La freccia centrale indica che il cancello in pausa Se lampeggia significa che attivo il conteggio del tempo per la chiusura autom...

Page 13: ...one e se necessario modificare la configurazione dei parametri desiderati 8 CARICAMENTO DEI PARAMETRI DI DEFAULT In caso di necessit possibile riportare tutti i parametri al loro valore standard o di...

Page 14: ...indicate nel punto 4 2 Questa posizione viene memorizzata come punto di chiusura dell anta 1 4 4 Viene effettuata una manovra di apertura per ciascuna anta l operazione termina quando si verifica una...

Page 15: ...enta la lettura del numero di cicli mancanti al prossimo intervento di manutenzione il valore arrotondato alle centinaia L area 3 rappresenta l impostazione di quest ultimo contatore alla prima pressi...

Page 16: ...ce successiva Premendo il tasto UP si ritorna alla voce precedente Premendo il tasto MENU si visualizza il valore attuale della voce selezionata e si pu eventualmente modificarlo L ultima voce di menu...

Page 17: ...Tempo di apertura parziale accesso pedonale 6 0 0 0 1 00 Se viene ricevuto un comando di Start Pedonale la centrale apre solo l anta 1 per un tempo regolabile da 0 secondi a 1 minuto Il massimo tempo...

Page 18: ...modo da facilitare lo sgancio Se il tempo t ASE inferiore a t SEr l eccitazione della serratura continua mentre le ante cominciano a muoversi mATTENZIONE Se il cancello non dotato di elettroserratura...

Page 19: ...e 1 0 0A 0 0A 14 0A Questo men permette la regolazione della sensibilit del sensore di ostacoli per il motore 1 Quando la corrente assorbita dal motore supera il valore impostato la centrale rileva un...

Page 20: ...icevuto un comando di Start Pedonale durante la fase di apertura parziale mATTENZIONE Un comando di Start ricevuto in qualunque fase dell apertura parziale provoca un apertura totale il comando di Sta...

Page 21: ...llo il tipo di lampeggio indica le quattro condizioni possibili CANCELLO FERMO luce spenta CANCELLO IN PAUSA la luce sempre accesa CANCELLO IN APERTURA la luce lampeggia lentamente 2Hz CANCELLO IN CHI...

Page 22: ...accende per 5 secondi no no Funzione disabilitata Si Funzione abilitata CoS1 Ingresso Costa Sensibile 1 Questo men permette di abilitare l ingresso per le coste sensibili di tipo 1 cio fisse no no Ing...

Page 23: ...l tempo necessario a recuperare lo spazio effettivamente percorso Questo potrebbe non essere sufficiente in particolare con cancelli molto pesanti perch a causa dell inerzia al momento dell inversione...

Page 24: ...non si apre e sul display appare la scritta Err3 Significa che fallito il test delle fotocellule 1 Assicurarsi che nessun ostacolo abbia interrotto il fascio delle fotocellule nel momento in cui stat...

Page 25: ...rrenti del motore anche necessario che la durata dell apertura e della chiusura siano di almeno 7 5 secondi Errore 9 Quando si cerca di modificare le impostazioni della centrale sul display compare la...

Page 26: ...ITALIANO 24...

Page 27: ...SHING LIGHT 5 9 LOCK 5 10 LIMIT SWITCH AND ENCODER 5 11 EXTERNAL AERIAL 5 12 PLUG IN RECEIVER 5 13 ADI INTERFACE 5 14 ELECTRIC CONNECTIONS 6 CONTROL PANEL 6 1 USE OF THE DOWN MENU AND UP KEYS FOR PROG...

Page 28: ...n IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires mechanical and electrical skills therefore it shall be carried out by quali...

Page 29: ...can be used for a signal light or a 24 V flashing light Auxiliary relay with programmable logic for courtesy light flashing light or other use ENERGY SAVING FUNCTION 5 INSTALLATION Installation of co...

Page 30: ...d receiver output of photocells 2 between terminals L8 PHOTO2 and L11 COM of the control unit Use outputs having normally closed contact mWARNING if several couples of same kind photocells are mounted...

Page 31: ...mmediately The direction of the gate at next command of START or PEDESTRIAN START depends upon the parameter STOP it inverts or continues the motion If the input STOP is disabled the command makes the...

Page 32: ...nd K5 COM Connect the open limit switch to motor 2 using terminals K3 FCA2 and K5 COM Connect the close limit switch to motor 2 using terminals K4 FCC2 and K5 COM Installation of encoders Connect the...

Page 33: ...al Devices Interface interface of the control unit CITY2 allows the connection to V2 optional modules Refer to V2 catalogue or to the technical sheets to see which optional modules with ADI interface...

Page 34: ...1 OPENING Z4 Motor 1 CLOSING Z5 Motor 2 OPENING Z6 Motor 2 CLOSING B1 B2 230VAC courtesy light or flashing light POW 24V power supply POW Power supply BAT pole of the optional battery pack code 161212...

Page 35: ...ENGLISH 33 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...

Page 36: ...as been caused by a safety device border or obstacle detector The central arrow shows that the gate is on pause If it blinks it means that the time countdown for the automatic closing has been activat...

Page 37: ...utomation work properly and if necessary modify the configuration of the desired parameters 8 LOADING OF DEFAULT PARAMETERS If necessary it is possible to restore all the parameters to their standard...

Page 38: ...nt for gate panel 2 4 3 Gate panel 1 is closed until one of the conditions listed in point 4 2 occur this position is memorized as the close point for gate panel 1 4 4 Each gate panel is opened The op...

Page 39: ...u can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of thi...

Page 40: ...item By pressing MENU you can view the current value of selected item and possibly change it The last menu item FinE allows storing the carried out changes and going back to the control unit normal op...

Page 41: ...ARNING if motor 2 is not connected this time must be set to zero t APP Partial opening time pedestrian access 6 0 0 0 1 00 When the control unit receives a Start Pedestrian command it will open leaf 1...

Page 42: ...lock is energized the gate will stay standstill for t ASE time to make its release easier In case t ASE is lower than t SEr the lock energizing will go on while the doors will start moving mWARNING i...

Page 43: ...tacle sensor for motor 1 0 0A 0 0A 14 0A This menu allows you to regulate the sensitivity of the obstacle sensor for motor 1 When the current absorbed by the motor exceeds the set value the controller...

Page 44: ...trol unit conduct in case it receives a Pedestrian Start command during the partial opening phase mWARNING a Start command in any phase of partial opening will cause the total opening the Start Pedest...

Page 45: ...eration Indicates the status of the gate in real time The type of blinking indicates the four possible conditions GATE STOPPED Light off GATE IN PAUSE the light is on fixed GATE OPENING the light blin...

Page 46: ...ll and the flashing light will stay onfor 5 sec The whole test cycle lasts less than one second no no Function deactivated Si Function activated CoS1 Safety ribbon 1 input This menu allows enabling th...

Page 47: ...ention of the photocell the set up time for the opposite movement would be excessive so the control unit operates the motors only for the time necessary to recover the actually covered journey This co...

Page 48: ...f learning procedure must be performed 3 With the encoders enabled and initialized a few seconds after movement begins This means that an encoder is NOT correctly operating Encoder malfunction or brok...

Page 49: ...he motor it is also necessary that the length of the opening and closure are at least of 7 5 second Error 9 When you are trying to change the control unit setups and the the display shows Err9 It mean...

Page 50: ...ENGLISH 48...

Page 51: ...0 FIN DE COURSE ET ENCODEUR 5 11 ANTENNE 5 12 RECEPTEUR EMBROCHABLE 5 13 INTERFACE ADI 5 14 BRANCHEMENTS ELECTRIQUES 6 PANNEAU DE CONTROLE 6 1 EMPLOI DES TOUCHES DOWN ET UP POUR LA PROGRAMMATION 7 CON...

Page 52: ...n vite que les partie en tension puissent aller en contact avec les parties faible tension de s curit Pour la connexion de tubes rigides ou flexibles utiliser des raccordements poss dant le IP55 nivea...

Page 53: ...Relais auxiliaire avec logique programmable pour clairage de courtoisie clignotant ou autre utilisation FONCTION ENERGY SAVING 5 INSTALLATION L installazione della centrale dei dispositivi di sicurez...

Page 54: ...tre les bornes L8 PHOTO2 et L11 COM de la centrale Utiliser des cellules avec contact normalement ferm mATTENTION Si on installe plusieurs couples de cellules du m me type ses sorties doivent etre bra...

Page 55: ...uivant le param tre programm dans la fonction STOP Si la fonction STOP est d shabilit e en programmation la commande provoque le d part dans le sens initial Si l entr e de STOP est d sactiv e la comma...

Page 56: ...re les bornes K3 FCA2 et K5 COM Relier la but e de fin de course de fermeture du moteur 2 entre les bornes K4 FCC2 et K5 COM Installation des encodeurs Relier l alimentation des deux encodeurs entre l...

Page 57: ...nnels de la ligne V2 R f rez vous au catalogue V2 ou la documentation technique pour voir quels modules optionnels avec interface ADI sont disponibles pour cette armoire de commande mATTENTION Pour l...

Page 58: ...Moteur 1 FERMETURE Z5 Moteur 2 OUVERTURE Z6 Moteur 2 FERMETURE B1 B2 Lumi re de courtoisie ou clignotant 230V POW Alimentation 24V POW Alimentation BAT P le du paquet batterie en option code 161212 o...

Page 59: ...FRAN AIS 57 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...

Page 60: ...fl che centrale indique que le portail est en tat de repos Si elle clignote cela signifie que le comptage du temps pour la fermeture automatique est actif La fl che plus en bas s allume quand le porta...

Page 61: ...position des rubriques l int rieur du menu et pour les options disponibles pour chaque rubrique il faut faire r f rence au paragraphe Configuration de l armoire 8 CHARGEMENT DES PARAM TRES PAR D FAUT...

Page 62: ...dans le point 4 2 ne se v rifie cette position est m moris e comme point de fermeture du vantail 1 4 4 Une manoeuvre d ouverture pour chaque vantail est effectu e l op ration se termine quand une des...

Page 63: ...s unit s L aire 2 repr sente la lecture du nombre des cycles manquants la prochaine entretien le valeur est arrondi la centaine L aire 3 repr sente l tablissement de ce dernier compteurs la premiers p...

Page 64: ...he UP on retourne au param tre pr c dent Appuyant la touche MENU on visualise la valeur actuelle du param tre s lectionn et on peut ventuellement la modifi e Le dernier param tre du FinE permet de m m...

Page 65: ...s branch ce temps doit tre tablit z ro t APP Temps ouverture partielle acc s pi tonne 6 0 0 0 1 00 S il re oit un commande de Start Pi tonne l armoire ouvre seulement le vantail pour un temps r duit L...

Page 66: ...temps t ASE ceci pour faciliter le d blocage Si le temps t ASE est inferieur t SEr l excitation de la serrure continue et les vantaux commencent bouger mATTENTION Si le portail n est pas dou d lectro...

Page 67: ...ur 1 0 0A 0 0A 14 0A Ce menu permet le r glage de la sensibilit du capteur d obstacles pour le moteur 1 Quand le courant absorb par le moteur d passe la valeur introduite l armoire rel ve une alarme Q...

Page 68: ...de l armoire s il re oit un commande de Start Pi tonne pendant la phase d ouverture partielle mATTENTION Un commande de Start re u en n importe quelle phase de l ouverture cause une ouverture totale...

Page 69: ...s possibles PORTAIL L ARRET lumi re teinte PORTAIL EN PAUSE la lumi re est toujours allum e PORTAIL EN OUVERTURE la lumi re clignote lentement 2Hz PORTAIL EN FERMETURE la lumi re clignote rapidement 4...

Page 70: ...ontraire il reste l arr t et le clignotant s allume pendant 5 sec L ensemble du cycle de test dure moins d une seconde no no Fonction d sactiv e Si Fonction activ e CoS1 Entr e barre palpeuse 1 Ce men...

Page 71: ...eulement pour le temps n cessaire r cup rer l espace effectivement parcours Ceci ne pourrait pas tre suffisant surtout avec portails tr s lourds car cause de l inertie au moment de l inversion le port...

Page 72: ...ra t Err3 Cela signifie que le test des cellules chou 1 S assurer qu aucun obstacle a interrompu le faisceau des photocellules au moment qu on a donn la commande de start 2 S assurer que les cellules...

Page 73: ...our la mesure des courants du moteur il est n cessaire aussi que la dur e de l ouverture et de la fermeture soient d au moins 7 5 secondes Erreur 9 Quand on essaye de modifier les r glages de l armoir...

Page 74: ...FRAN AIS 72...

Page 75: ...TOR TOPE DE RECORRIDO Y CODIFICADOR 5 11 ANTENA EXTERNA 5 12 RECEPTOR ENCHUFABLE 5 13 INTERFAZ ADI 5 14 CONEXIONES ELECTRICAS 6 PANEL DE CONTROL 6 1 UTILIZACION DE LAS TECLAS DOWN MENU Y UP PARA LA PR...

Page 76: ...na desconexi n accidental de un cable que las partes con tensi n de red entren en contacto con las partes en baja tensi n de seguridad Para la conexi n de tubos r gidos o flexibles y pasacables utiliz...

Page 77: ...en baja tensi n utilizable por una l mpara piloto o por una luz intermitente de 24 V Rel auxiliar con l gica programable para luces de cortes a intermitentes o bien otra utilizaci n Funci n ENERGY SA...

Page 78: ...L11 COM del cuadro y la salida de los receptores de las fotoc lulas del tipo 2 entre los bornes L8 PHOTO2 y L11 COM del cuadro Utilizar las salidas con contacto normalmente cerrado mATENCION Si se in...

Page 79: ...RT o START PEATONAL depende del par metro STOP invierte o prosigue el movimiento Si la entrada de STOP est deshabilitada el comando reemprende el movimiento en la misma direcci n Si la entrada de STOP...

Page 80: ...de apertura del motor 2 entre los bornes K3 FCA2 y K5 COM Conecte el interruptor de tope de cierre del motor 2 entre los bornes K4 FCC2 y K5 COM Instalaci n de los codificadores Conecte la alimentaci...

Page 81: ...conexi n con una serie de m dulos opcionales de la l nea V2 Hacer referencia al cat logo V2 o a la documentaci n t cnica para ver que modulos opcionales con interfaz ADI estan disponibles para el cuad...

Page 82: ...RE Z5 Motor 2 APERTURA Z6 Motor 2 CIERRE B1 B2 Luz de cortes a o intermitente de 230V POW Alimentaci n 24V POW Alimentaci n BAT Polo del paquete bater a opcional cod 161212 o del box bater a ECO LOGIC...

Page 83: ...ESPA OL 81 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...

Page 84: ...vo de seguridad banda o sensor de obstaculos La flecha central indica que la puerta est en pausa Si parpadea significa que est activado el tiempo para el cierre autom tico La flecha m s abajo se encie...

Page 85: ...la automaci n y si es necesario modificar la configuraci n de los par metros deseados 8 CARGA DE LOS PAR METROS POR DEFECTO Si fuese necesario es posible devolver todos los par metros a sus valores e...

Page 86: ...n el punto 4 2 Esta posici n se memoriza como punto de cierre de la hoja 1 4 4 Se efect a entonces una maniobra de apertura para cualquier hoja terminando la operaci n cuando se verifica una de las co...

Page 87: ...de ciclos que faltan para la pr xima intervenci n de mantenimiento el valor est redondeado a los centenares El rea 3 representa la programaci n de este ltimo contador a la primera pulsaci n de la tec...

Page 88: ...e a la voz anterior Pulsando la tecla OK se visualiza el valor actual de la voz seleccionada y eventualmente se puede modificar La ltima voz de men FinE permite memorizar las modificaciones efectuadas...

Page 89: ...cta el motor 2 este tiempo tiene que ser programado a cero t APP Tiempo de apertura parcial entrada peatonal 6 0 0 0 1 00 Si se recibe un comando de Start Peatonal el cuadro abre solo la hoja 1 por un...

Page 90: ...iempo t ASE para facilitar el desenganche Si el tiempo t ASE es inferior a t SEr el funcionamiento de la cerradura continua mientras las hojas empiezan a moverse mATENCION Si la puerta no est dotada d...

Page 91: ...motor 1 0 0A 0 0A 14 0A Este men permite la regulaci n de la sensibilidad del sensor de obst culos para el motor 1 Cuando la corriente absorbida por el motor supera el valor programado la centralita o...

Page 92: ...en permite establecer el comportamiento del cuadro si se recibe un comando de Start Peatonal durante la fase de apertura parcial mATENCION Un comando de Start recibido en cualquier fase de la apertura...

Page 93: ...sibles CANCELA DETENIDA luz apagada CANCELA EN PAUSA la luz est siempre encendida CANCELA EN APERTURA la luz parpadea lentamente 2 Hz CANCELA EN CIERRE la luz parpadea r pidamente 4 Hz LP PA L mpara d...

Page 94: ...activada CoS1 Entrada Banda de Seguridad 1 Este men permite habilitare la entrada para las banda de seguridad de tipo 1 las fijas no no Entrada deshabilitada el cuadro de maniobras lo ignora AP Entra...

Page 95: ...lo por el tiempo necesario para recuperar el espacio realmente recorrido Este podr a no ser suficiente sobre todo para puertas muy pesadas puesto que a causa de la inercia en el momento de la inversi...

Page 96: ...a Err3 Significa que ha fallado el test de las fotoc lulas 1 Asegurarse de que ning n obst culo haya interrumpido el rayo de las fotoc lulas en el momento que se ha dado el comando de start 2 Asegurar...

Page 97: ...tecci n de la corriente del motor es tambien necesario que la duraci n de la apertura y del cierre sean al menos de 7 5 segundos Error 9 Cuando se intenta modificar las programaciones del cuadro y en...

Page 98: ...ESPA OL 96...

Page 99: ......

Page 100: ...S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com FRANCE AFCA V2 SAS 4 bis rue Henri Becquerel B P 43 69740 GENAS FRANCE Tel 33 4 72...

Reviews: