ENGLISH
- 45 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
i.Adi
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI connector.
PLEASE NOTE
: selecting
Si
and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each device.
Please refer to the manual for the device.
If the
Si
option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the
i.Adi
option
no
no
Interface disabled
Si
Interface enabled
ASM
Anti-skid
When an opening or closing operation is interrupted by a command or
for the intervention of the photocell, the set-up time for the opposite
movement would be excessive, so the control unit operates the motors
only for the time necessary to recover the actually covered journey.
This could be not sufficient, particularly in the case of very heavy gates,
as because of the inertia at the inversion moment the gate runs an extra
space in the previous direction that the control unit is not able to take
into account. If after an inversion the gate does not return exactly to the
starting position, it is possible to set an anti-skid time that is added to the
time calculated by the control unit in order to recover the inertia.
no
no
Function disabled
0.5” - 3.0”
Anti-skid time
FinE
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
no
no
It does not exit from the program menu
Si
It exits from the program menu by storing the setup parameters