DISPLAY
DATA
FUNCTION
DEFAULT MEMO
Pot
Motor power
60
30 - 1 00
The displayed value is the percentage of max. motor power
P.rA L
Power motor during slow-down phase
20
0 - 70
The value displayed represents the percentage of the maximum motor power
P.bA t
Maximum motor power during battery operation
no
no - Si
This menu allows you to activate the motors at their maximum power
during battery operation
SPUn
Start off
no
no - Si
If this function is activated, for the first 2 seconds of motion of each door, the
control unit will ignore
Pot
value and it will give motor the maximum power
command in order to overcome the gate inertia
rA M
Starting ramp
6
6 - 0
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
SEnS
Adjusting the obstacle sensor
no
no
Function deactivated
1 .0A- 1 0.0A
This menu allows adjustment of the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the value set, the
control unit detects an alarm
rA .A P
Slow down in opening
1 5
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
rA .Ch
Slow down in closing
1 5
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
St .A P
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
PA US
PA US
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St .Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
A PEr
The gate opens again
St .PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
ChiU
ChiU
The gate starts closing
no
Command is ignored
PA US
The pause time is reset (
Ch.A U
)