4 - CONTROL UNIT

PD13

is provided with a display that, not only makes 

programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.

In compliance with the European standards concerning 
electrical safety and electromagnetic compatibility 
(EN 60335-1, EN 50081-1 and EN 50082-1) it has been 
equipped with the low voltage circuit total electric insulation
(motors included) from the network voltage.

Other characteristics:
• Power supply protected from short circuits within the 

controller, on the motors and on the connected accessories.

• Adjustment of the power by partializing the current.
• Detecting obstacles by monitoring the current on the motors 

(current sensing probe and encoder)

• Automatic learning of the limit switch position
• Tests for safety devices (photocells, safety ribbons and 

mosfet) before each opening.

• Deactivation of safety inputs through the configuration 

menu: no jumper is required for terminals concerning safety 
devices that have not been installed, yet.  You will only need 
to disable this function from its relevant menu. 

• The device can operate without mains power, by using the 

optional battery pack (code 161212).

• Low voltage output that can be used for a signal light or a 

24 V flashing light.

• Auxiliary relay with programmable logic for courtesy light, 

flashing light or other use.

• ENERGY SAVING FUNCTION
• Synchronized operation of two motors using the SYNCRO

optional module (compatible with the control units PD13 from
version 1.1 onward)

m

Installation of control unit and safety devices must 

be carried out with power disconnected.

4.1 - CONNECTING THE MOTOR, LIMIT
SWITCH SENSOR AND ENCODER

The motor, limit switch sensor card and encoder are already
connected to the PD13 control unit by means of polarised
connectors.

m

CAUTION: Never reverse the connectors

4.2 - ACTIVATION INPUTS

PD13 control unit is equipped with two activation inputs 
(START and START P.), whose operation depends on the
programmed operation modes (see 

Strt

item of programming

menu):

Standard mode

START = START (a command will cause the complete 
opening of the gate)
START P. = PEDESTRIAN START (a command will cause the 
partial opening of the gate)

Open/Close command

START = OPENING (always controls the gate opening) 
START P. = CLOSING (always controls the gate closing) 
This is an impulse command, that is to say that an impulse 
will cause the complete gate opening or closing.

Manned operation

START = OPENING (always controls the gate opening) 
START P. = CLOSING (always controls the gate closing) 
This is a monostable command, that is to say, the gate will 
be opened or closed as long as the contact is closed and it 
will immediately stop as the contact is open

Timer mode

This function allows programming the gate opening time 
during the day, by making use of an external timer. 

START = START (a command will cause the complete 
opening of the gate)
START P. = PEDESTRIAN START (a command will cause the 
partial opening of the gate)
The gate stays open (completely or partially) while the contact 
is closed on input; as soon as the contact is open the pause 
time count down will start, after which the gate will be 
closed again. 

ATTENTION: Automatic closing must be enabled

In all modes, inputs must be connected to devices having 
normally open contacts.

Connect cables of device controlling the first input between 
terminals 

J1 (START)

and 

J4 (COM)

of the control unit.

Connect cables of device controlling the second input between
terminals 

J2 (START P.)

and 

J4 (COM)

of the control unit.

The START input function can also be activated by pressing 

h

key

(outside the programming menu) or by means of a remote
control stored on channel 1 of MRx receiver.

The START P. input function can also be activated by pressing 

i

key (outside the programming menu) or by means of a remote
control stored on channel 2 of MRx receiver.

MOTOR

LIMIT SENSOR

ENCODER

J9

J8

J7

J6

J5

J4

J3

J2

J1

B1 B2

E5

E3

E4

E2

E1

Summary of Contents for ALFARISS

Page 1: ...EUR ELECTROMECANIQUE 24V IRREVERSIBLE A CREMAILLERE POUR PORTAILS COULISSANTS JUSQU A 300 KG DE POIDS MOTOR ELECTROMECANICO 24V IRREVERSIBLES A CREMALLERA PARA PUERTAS CORREDERAS HASTA 300 KG DE PESO...

Page 2: ......

Page 3: ...34 4 2 ACTIVATION INPUTS 34 4 3 STOP 35 4 4 CONNECTING PHOTOCELLS 35 4 5 CONNECTING SAFETY RIBBONS 35 4 6 EXTERNAL AERIAL 36 4 7 LOW VOLTAGE LIGHT OUTPUT 36 4 8 COURTESY LIGHTS 36 4 9 POWER SUPPLY 36...

Page 4: ...y and hazard warnings on the machinery and equipment should be complied with Electromechanical actuators for gates are not intended to be used by people including children with diminished physical sen...

Page 5: ...t person The risk analysis should take into consideration all danger zones for the automation device which should be appropriately protected and marked In a clearly visible area apply a sign with info...

Page 6: ...50 Idling current A 0 9 Full load current A 3 Gate maximum speed m s 0 18 Maximum thrust N 330 Duty cycle 50 Pinion M4 Z16 Working temperature C 20 55 Motor weight Kg 7 5 Protection degree IP 44 Maxim...

Page 7: ...and parallel to the gate 5 Wait for the complete setting of the concrete 6 Unscrew the bolts fixing the base to the clamps and put the motor on the plate 7 Insert the 4 grains with their nuts in the p...

Page 8: ...gate making sure that they stand at the same height than the motor pinion The rack MUST BE positioned 1 or 2 mm over the pinion of the motor all the gate length 3 4 INSTALLING THE MAGNETIC LIMIT SWITC...

Page 9: ...restore the automation proceed as follows 1 Turn the key L anticlockwise until reached the limit switch then draw it out 2 Turn the key K anticlockwise closing the hatch of the lock then draw it out...

Page 10: ...rse the connectors 4 2 ACTIVATION INPUTS PD13 control unit is equipped with two activation inputs START and START P whose operation depends on the programmed operation modes see Strtitem of programmin...

Page 11: ...control unit Use outputs having normally closed contact mSAFETY RIBBONS INSTRUCTIONS If several edges with normally closed contacts are used the outputs should be connected in series If several conduc...

Page 12: ...VER PD13 control unit is suitable for plugging in a MRx receiver having a high sensitivity super heterodyne architecture MRx module receiver is provided with 4 channels and each of them is suitable fo...

Page 13: ...ing traditional devices with N O contact J2 Pedestrian open command for connecting traditional devices with N O contact J3 STOP command N C contact J4 Common J5 Photocell 1 xterior N C contact J6 Phot...

Page 14: ...explored by using the 3 keys h i and OK located on the side of the control unit display PLEASE NOTE Outside the configuration menu pressing the h key activates the START command pressing the i key ac...

Page 15: ...ges which will get lost 7 LOADING THE DEFAULT PARAMETERS dEF If necessary it is possible to restore all parameters to their standard or default values see the final summary table m PLEASE NOTE This pr...

Page 16: ...ached 5 2 The gate will be activated in opening direction until the stop end or the opening end of stroke is reached 5 3 The gate will be activated in closing direction until the stop end or the closi...

Page 17: ...cell edge limit switches or encoder To start the emergency dead man operating mode activate the start command START for 3 seconds Note if the Strt parameter is set as StAn the Start command from the t...

Page 18: ...eys you can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup...

Page 19: ...unction This function is useful for reducing the energy consumption of the automation device while in stand by mode If the function is enabled the control unit will enter ENERGY SAVING mode under the...

Page 20: ...y of the obstacle sensor When the current absorbed by the motor exceeds the value set the control unit detects an alarm rA AP Slow down in opening 1 5 0 1 00 This menu allows regulating the percentage...

Page 21: ...the pause If the photocell operates during the opening time this time will be immediately stored as pause time This function allows having a fast closing as soon as transit through the gate is comple...

Page 22: ...rol unit ProS The input STOP stops the gate pressing the command START the gate continues the motion invE The command STOP stops the gate at the next START the gate starts moving in the opposite direc...

Page 23: ...reshold indicates the presence of an obstacle If set to 0 the obstacle is only detected when the gate is stopped When the sensor intervenes the gate stops and is operated in the reverse direction for...

Page 24: ...ed section 4 4 Error 4 When a Start command is given and the gate does not open or does a partial opening and the display shows Err4 It means that the end of stroke is damaged or that the wiring that...

Page 25: ...com 14 MAINTENANCE Maintenance should be performed in full compliance with the safety instructions described in this manual and in accordance with current legal and regulatory provisions The recommend...

Page 26: ...ENGLISH 50...

Page 27: ...months for normal domestic use but this period may vary depending on the intensity of use Any inspection maintenance or repairs should only be performed by qualified personnel Even if you think you kn...

Page 28: ...ENGLISH 52...

Page 29: ......

Reviews: