2. Remove cover from inverter.
3. Disconnect cable connections.
4. Release fastening screws.
5. Replace compressor.
6. Tighten screws on compressor, connect cable and put
cover on inverter.
7. Solder connections and desiccant cartridge.
Non-speed controlled (old) compressor
(De Luxe, Perfect)
1.
Using soldering flame, heat up and release
compressor connections.
2.
Remove protective cap from connection box
and loosen strain relief screws.
3.
Disconnect cable connections.
4.
Release fastening screws.
5.
Replace compressor.
6.
Tighten screws on compressor, connect
cable and attach protective cap.