5. Power socket defective.
Mains connection trouble-shooting
must be carried out by a qualified
electrician.
6. Demo operating mode is
active and demo is shown in
the display.
Deactivate demo mode (see section
4.6).
The cooling
temperature is
insufficient.
1. Temperature is not set
correctly.
Set the temperature (see section 4.3)
2. Appliance door open for
longer length of time.
Avoid leaving appliance door open for
longer than 2 to 3 minutes (alarm
sounds after 10 minutes and can be
stopped by briefly pressing any
button).
3. Check door seal.
Replace door seal (see section 7.5).
4. Appliance standing next to
heat source.
5. Door is not hanging straight.
Set the door (see section
Fehler!
Verweisquelle konnte nicht
gefunden werden.Fehler!
Verweisquelle konnte nicht
gefunden werden.
).
6. Faulty temperature sensor.
Check temperature sensor (see
section 7.3).
7. Compressor defective
(irregular operating noise)
Danger of explosion
Repair work must only be carried out
in a suitably equipped workshop!
Interior illumination
not working
1. LED defective.
Replace LED (see section 7.2).
2. LED plug not inserted
correctly.
Check plug connection (see section
7.2).
3. Magnet for door contact
missing.
Check illumination switch (see section
0).
Light not working.
1. Magnet missing.
Check illumination switch (see section
0).
2. Spring missing.
Put in spring (see section
Button not reacting.
Static charge of operating panel
Use an earthing strap or hold the
operating panel and hinge at the
same time.