Service manual Platform 2014-2016, V-ZUG KT
1036497-00_ae gedruckt
Icing-up
1. Faulty installation.
Check installation (200 cm
2
ventilation
slits).
Magnetic door seal sitting flush and
tight in groove.
Make sure door closes too
properly.
Air gap between frame and
housing.
SoftClose with closing guarantee.
2. Door panel catching.
Adjust door panel.
3. Warm food
Allow food to cool down before
placing in refrigerator.
4. Moist foodstuffs.
Keep food covered in refrigerator.
5. Food touching rear wall.
Keep food clear of rear wall.
6. Hinge covers too high.
Replace round-head screw with
countersunk-head screw.
7. Temperature too low.
Check set temperature.
Noise
1. Vibration above niche.
Check installation. Does appliance
stand straight in niche?
2. Compressor defective
Replace compressor (see section
7.13).
3. Air in circuit
Evacuate refrigerant cooling circuit
and then refill again (see sections 7.8
and 7.9)
4. Ventilation not correct
(compressor always running)
Check installation (is ventilation cross-
section large enough?)
5. Solenoid valve not engaged in
mounting.
Engage solenoid valve.
6. Condenser not securely
fastened to housing.
Fasten condenser securely.
7. Condenser touching cables.
Avoid contact with condenser and
cables.
8. Cold storage compartment fan
catching or unbalanced.
Check and correct fan installation.
Replace fan.
Temperature display
flashing
Power failure
The temperature after the power
failure is displayed. Press any button.
For Cooltronic/eco, Noblesse/eco, Prestige/T/eco/P eco
Malfunction
Possible cause
Solution
Cooling
compartment too
warm or too cold.
Faulty valve
Test valve function using the
service mode.
- Valve function faulty => replace
control unit and retest valve.
- Valve function still faulty => put old
control unit back in and replace