7
REPAIRS
7.1
Checking illumination switch
Always disconnect the refrigerator from the mains before working on
the electrical system!
Electrical safety (protection against contact) must be ensured by the
installation!
Cooling compartment illumination
1.
Interior illumination comes on when the
appliance door is opened.
2.
And when the appliance door is closed, the
interior illumination must turn off.
3.
If the interior illumination does not turn off,
check that the door magnet is in place.
4.
If yes, change electronics.
Freezer compartment illumination
5.
Contact switch for door in freezer
compartment