background image

Installation instructions

Heat pump dryer
One-family household

1068340-R02

22/05/2019

1068340-R02

4

Washer-dryer towers

Failure to use the correct installation plate can result in damage to the appliance!

Use the installation plate supplied to install the washing machine. The use of an unsuitable installation plate or a soft, sound-
insulating underlay can cause damage to the appliance which does not fall within the scope of the manufacturer’s guarantee.

Tumble dryer

12011–12013

Washing machine

11001–11006, 11010–11014, 11021, 11023, 11025

K

S

1

Take out the double-sided adhesive tape

S

 and adhere to the mounting surfaces

K

.

2

3

Turn over the installation plate. Push to
the front edge of the washing machine
cover plate (see arrow) and adhere into
place.

Take the tower panel out of its fixture on
the back of the tumble dryer.

Install the tower panel on the mounted
installation plate.

Tumble dryer

12011–12013

Washing machine

265, 266, 268, 269

U

S

P

P

P

1

2

B

U

12 mm

6 mm

Click in the six positioning cams 

P

.

Cut out the mounts 

U

.

Adhere the double-sided adhesive tape

S

 to both sides of the mounts 

U

.

Turn over the installation plate.

Adhere the mounts 

U

 to the 4 mounting

surfaces 

B

 precisely.

3

4

Turn over the installation plate. Push to
the front edge of the washing machine
cover plate (see arrow) and adhere into
place.

Take the tower panel out of its fixture on
the back of the tumble dryer.

Install the tower panel on the mounted
installation plate.

Summary of Contents for AT6TWHWR

Page 1: ...drum and in the appliance packaging Designation Article no Number See installation step Installation plate incl double sided adhesive tape W40653 1 2 Positioning the installation plate Tower panel W5...

Page 2: ...ng walls of their installation location 1160 1200 180 180 1200 1160 595 70 15 600 500 50 57 5 3 6 1 5 126 444 280 850 2 4 550 458 71 Left hand opening Right hand opening 1 Cooling air inlet 2 Cooling...

Page 3: ...ll 3 1 2 2 6 Variant 1 Without underfloor heating Fasten installation plate to the floor with 3 screws Dampen mounting slots E with water to make the appliance easier to push in Variant 2 With underfl...

Page 4: ...K 2 3 Turn over the installation plate Push to the front edge of the washing machine cover plate see arrow and adhere into place Take the tower panel out of its fixture on the back of the tumble dryer...

Page 5: ...605 860 1710 45 Centre the installation plate in the niche Distance to the back wall 45 mm Cut out for lateral connections left or right 100 100 mm Niche height for tumble dryer 860mm Niche height fo...

Page 6: ...pliance 3 Inserting the ventilation grille 1 400 cm 1710 50 400 cm 860 The heat given off from the rear of the appliance must be conducted out of the niche Insert 2 ventilation grilles P33002 or a ven...

Page 7: ...arth conductors ensure safe and fault free operation After installation live parts and cables with basic insulation must not be accessible Check old installa tions The appliance is designed for use up...

Page 8: ...le dryer and the level of the water in the drain trap Position the drain hose from the tumble dryer above the overflow line U Do not exceed the maximum pumping height Max pumping height 1200 mm Max pu...

Page 9: ...he function test can be started imme diately after installation It cannot be aborted by interrupting the power supply Once the function test has been run or aborted it can no longer be selected and th...

Reviews: