5. Electrical connections
Electrical connections
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
▸
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
▸
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The mains plug must not be cut off.
Connection cable
Valid for all washing machines and tumble dryers in the Adora, AdoraWash and AdoraDry model range.
The mains cable may only be replaced by the manufacturer, its Customer Services or a similarly qualified person.
Error messages «U1»
Disconnect the appliance from the mains and control the wiring.
6. Connecting condensate drain
Fastening the drain hose
When installing the drain hose, protect it against damage and kinks!
Fasten the drain hose before plugging in the mains cable.
1
2
A
C
B
D
3
▸
Remove the pump cover
A
.
▸
Fasten the drain hose
B
to nozzle
D
us-
ing the hose clip
C
.
▸
Put back the pump cover
A
.
▸
Plug in the mains cable.