Installation instructions

Heat pump dryer
One-family household

1068340-R02

22/05/2019

1068340-R02

8

Connecting condensate drain

The drain hose for the tumble dryer must not be lengthened!

Otherwise water from the drain hose of the tumble dryer can flow into the condensate tank of the tumble dryer when the con-
densate pump is switched off.

Never connect the drain hose from a tumble dryer to the drain hose from a washing machine so that it is watertight
(hydraulically)!

Otherwise water from the drain hose of the washing machine can flow into the condensate tank of the tumble dryer!

Do not immerse the end of the drain hose from the tumble dryer in the water in the drain trap!

Otherwise water in the drain-trap bend can flow into the condensate tank when the condensate pump is switched off.

Single connections

Drainage into fixed upright outflow pipe
(W56298)

Connection to sink drain trap (W53070)

Work steps

≤1200

≤1200

U

Use an open-top fixed upright outflow
pipe with the drain trap.

Leave a gap of ≥5 cm between the end
of the drain hose from the tumble dryer
and the level of the water in the drain
trap.

Position the drain hose from the tumble
dryer above the overflow line 

U

. Do not

exceed the maximum pumping height!

Max. pumping height: 1200 mm

Max. pumping height: 1200 mm

Tumble dryer positioned next to washing machine (open-top fixed upright outflow pipe)

Fixed upright outflow pipe with separ-
ately routed drainage pipe

Fixed upright outflow pipe with combi
drainage set (W55969)

Work steps

≤1200

U

≤700

Use an open-top fixed upright outflow
pipe with the drain trap.

Leave a gap of ≥5 cm between the end
of the drain hose from the tumble dryer
and the level of the water in the drain
trap.

Insert the drain hoses from both appli-
ances into the riser pipe of the drain trap.

Position the drain hose from the tumble
dryer above the overflow line 

U

. Do not

exceed the maximum pumping height!

Max. pumping height: 1200 mm

Max. pumping height: 700 mm

Tumble dryer positioned next to washing machine (GEBERIT concealed drain trap)

Cannot be connected to a concealed double drain trap! There must be a separate concealed drain trap for each appli-
ance.

Y

X

X

Washing machine: Use concealed drain
trap GEBERIT UP 

Y

 (GEBERIT art. no.

152.236.00.1).

Tumble dryer: Use concealed drain trap
GEBERIT UP 

X

 (GEBERIT art. no.

152.237.00.1).

Summary of Contents for AT6TWHWR

Page 1: ...drum and in the appliance packaging Designation Article no Number See installation step Installation plate incl double sided adhesive tape W40653 1 2 Positioning the installation plate Tower panel W5...

Page 2: ...ng walls of their installation location 1160 1200 180 180 1200 1160 595 70 15 600 500 50 57 5 3 6 1 5 126 444 280 850 2 4 550 458 71 Left hand opening Right hand opening 1 Cooling air inlet 2 Cooling...

Page 3: ...ll 3 1 2 2 6 Variant 1 Without underfloor heating Fasten installation plate to the floor with 3 screws Dampen mounting slots E with water to make the appliance easier to push in Variant 2 With underfl...

Page 4: ...K 2 3 Turn over the installation plate Push to the front edge of the washing machine cover plate see arrow and adhere into place Take the tower panel out of its fixture on the back of the tumble dryer...

Page 5: ...605 860 1710 45 Centre the installation plate in the niche Distance to the back wall 45 mm Cut out for lateral connections left or right 100 100 mm Niche height for tumble dryer 860mm Niche height fo...

Page 6: ...pliance 3 Inserting the ventilation grille 1 400 cm 1710 50 400 cm 860 The heat given off from the rear of the appliance must be conducted out of the niche Insert 2 ventilation grilles P33002 or a ven...

Page 7: ...arth conductors ensure safe and fault free operation After installation live parts and cables with basic insulation must not be accessible Check old installa tions The appliance is designed for use up...

Page 8: ...le dryer and the level of the water in the drain trap Position the drain hose from the tumble dryer above the overflow line U Do not exceed the maximum pumping height Max pumping height 1200 mm Max pu...

Page 9: ...he function test can be started imme diately after installation It cannot be aborted by interrupting the power supply Once the function test has been run or aborted it can no longer be selected and th...

Reviews: