background image

Installation instructions

Heat pump dryer
One-family household

1014097-R05

07/11/2017

1014097-R05

3

Positioning in a niche

If a tumble dryer or a washer-dryer tower is installed in a niche, a 130° door stop must be provided (article no.
W54086).

If the niche is fitted with a door, it must be ensured that the door is left open for the duration of the process. The
niche door and the appliance door must be hinged on the same side.

A

≥600

B

Cut-out for lateral 
connection, 
to the left or right
≥100 × 100 mm

Niche height
≥860 mm!

Centre the installation plate in the niche.

If a device is installed with the V-ZUG Home option:

Connect the network cable to the device.

Variant

Positioning

Niche depth 

A

Installation offset 

for installation plate 

B

1

Appliance door flush with niche front

≥605 mm

50 mm

2

Appliance door recessed behind niche front

≥645 mm

90 mm

Variant 1

Variant 2

B

A

Appliance door

Installation plate

Niche

Appliance door 
flush with front edge 
of niche 

A

B

≥20

A

Appliance door

Installation plate

Niche

B

The condensed water hose must not be crushed between the rear of the appliance and the building wall.

Summary of Contents for Adora TSLQ WP

Page 1: ...ing drum and in the appliance packaging Designation Article no Number See installation step Installation plate incl double sided adhesive tape W40653 1 1 Positioning the installation plate Tower panel...

Page 2: ...e the installation plate to the floor with double sided ad hesive tape S Dampen the mounting slots E on the installation plate with wa ter This makes it easier to push the appliance in Free standing p...

Page 3: ...connection to the left or right 100 100 mm Niche height 860 mm Centre the installation plate in the niche If a device is installed with the V ZUG Home option Connect the network cable to the device V...

Page 4: ...6 11013 and SLQ WP 11004 11014 P Click in the six positioning cams P K S Take out the double sided adhesive tape S and adhere to the mounting surfaces K Tumble dryer Models 12004 12005 12006 Washing m...

Page 5: ...2 Take the tower panel 1 out of its fixture 2 on the back of the tumble dryer 3 1 Install the tower panel 1 on the mounted installation plate 3 2 Inserting the ventilation grille The heat given off f...

Page 6: ...ug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as isolating devices Effective earthing and separ...

Page 7: ...A D B C Fasten the drain hose B to nozzle D using the hose clip C Put back the pump cover A Single connections The drain hose must not be submerged in the water in the drain trap Maximum pumping heig...

Page 8: ...n be connected to a double drain trap Drainage into fixed upright outflow pipe with separately routed drainage pipe Drainage into fixed upright outflow pipe with combi drainage set W55969 1200 800 700...

Page 9: ...Carrying out the function test Work steps 12004 12005 12006 Plug appliance in at mains In the display appears English fr it rm OK Language English Select language for function test Press to change lan...

Reviews: