background image

Installation instructions

Heat pump dryer
One-family household

1014097-R05

07/11/2017

1014097-R05

4

Positioning on washing machines

1.

Affixing with adhesive tape

Tumble dryer

Models 12004, 12005, 12006

Washing machine

Models L (11001, 11010), S (11002, 11011), SL (11003, 11012), SLQ (11006, 11013) and SLQ WP
(11004, 11014)

P

Click in the six positioning cams 

P

.

K

S

Take out the double-sided adhesive tape 

S

 and adhere to the

mounting surfaces 

K

.

Tumble dryer

Models 12004, 12005, 12006

Washing machine

Models L (265), S (266), SL (268) and SLQ (269)

U

S

Cut the double-sided adhesive tape 

S

 into two down the centre.

Cut out the mounts 

U

.

Adhere the double-sided adhesive tape 

S

 to both sides of the

mounts 

U

.

B

U

12 mm

6 mm

Adhere the mounts 

U

 to the mounting surfaces 

B

 precisely.

Summary of Contents for Adora TSLQ WP

Page 1: ...ing drum and in the appliance packaging Designation Article no Number See installation step Installation plate incl double sided adhesive tape W40653 1 1 Positioning the installation plate Tower panel...

Page 2: ...e the installation plate to the floor with double sided ad hesive tape S Dampen the mounting slots E on the installation plate with wa ter This makes it easier to push the appliance in Free standing p...

Page 3: ...connection to the left or right 100 100 mm Niche height 860 mm Centre the installation plate in the niche If a device is installed with the V ZUG Home option Connect the network cable to the device V...

Page 4: ...6 11013 and SLQ WP 11004 11014 P Click in the six positioning cams P K S Take out the double sided adhesive tape S and adhere to the mounting surfaces K Tumble dryer Models 12004 12005 12006 Washing m...

Page 5: ...2 Take the tower panel 1 out of its fixture 2 on the back of the tumble dryer 3 1 Install the tower panel 1 on the mounted installation plate 3 2 Inserting the ventilation grille The heat given off f...

Page 6: ...ug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as isolating devices Effective earthing and separ...

Page 7: ...A D B C Fasten the drain hose B to nozzle D using the hose clip C Put back the pump cover A Single connections The drain hose must not be submerged in the water in the drain trap Maximum pumping heig...

Page 8: ...n be connected to a double drain trap Drainage into fixed upright outflow pipe with separately routed drainage pipe Drainage into fixed upright outflow pipe with combi drainage set W55969 1200 800 700...

Page 9: ...Carrying out the function test Work steps 12004 12005 12006 Plug appliance in at mains In the display appears English fr it rm OK Language English Select language for function test Press to change lan...

Reviews: