Level limit switch
Series RF 3000
Technical Information / Instruction manual
page
Notes for use in Hazardous Locations
Max. Surface Temperature and Temperature Class
The temperature marking on the name plate refers to the instruction manual.
On the following tables the relevant temperature ratings are shown.
The maximum surface temperature (resp. temperature class) is the warmest temperature of the unit which could occur during
malfunction (according to Ex-definition).
ambient side
process side
Permitted zones (categories) for mounting in partition wall
EPL
Db
Gb
Db
Category
2D
2G
2D
Zone
21
1
21
EPL
Da
Gb
Da
Category
1D
2G
1D
Zone
20
1
20
Rod
Rope
Rod,
remote
version
Rope,
remote
version
Standard
housing
d-housing
de-housing
With
Standard
housing
With
d- and de-
housing
RF 3100
RF 3200
RF 3300
Compact version:
Ambient temperature
range
Max. process
temperature
Max. Surface
temperature
(EPL Db)
Max. Surface
temperature
(EPL Da)
Temperature
class
(EPL Gb)
-20 .. +70°C
(-4 .. +158°F)
(1)
-40 .. +70°C
(-40 .. +158°F)
(2)
-40 .. +60°C
(-40 .. +140°F)
(3)
80°C (176°F)
120°C (248°F)
T
200
120°C (248°F)
T4
120°C (248°F)
120°C (248°F)
T
200
120°C (248°F)
T4
250°C (482°F)
250°C (482°F)
T
200
250°C (482°F)
T2
445°C (833°F)
(4)
445°C (833°F)
(4)
T
200
445°C (833°F)
(4)
T1
(4)
Remote version electronic enclosure:
Ambient temperature
range
Max. Surface temperature
(EPL Db)
Temperature class
(EPL Gb)
-20 .. +70°C
(-4 .. +158°F)
(1)
-40 .. +70°C
(-40 .. +158°F)
(2)
-40 .. +60°C
(-40 .. +140°F)
(3)
120°C (248°F)
T4
Remote version junction box and probe:
Ambient temperature
range
Process
temperature
range
Max. Surface
temperature
(EPL Db)
Max. Surface
temperature
(EPL Da)
Temperature
class
(EPL Gb)
-20 .. +70°C
(-4 .. +158°F)
(1)
-40 .. +70°C
(-40 .. +158°F)
(2)
80°C (176°F)
120°C (248°F)
T
200
120°C (248°F)
T6
120°C (248°F)
120°C (248°F)
T
200
120°C (248°F)
T4
250°C (482°F)
250°C (482°F)
T
200
250°C (482°F)
T2
445°C (833°F)
(4)
445°C (833°F)
(4)
T
200
445°C (833°F)
(4)
T1
(4)
(1) For versions with plastic enclosure
(2) For versions with standard enclosure (metal)
(3) For versions with d- and de- enclosure
(4) Only with RF 3300
RFnivo
®
1
2
3
4
5
6
7
8
9
10
11
12
RF 3000 f
gi241014
42