Level limit switch
Series RF 3000
Technical Information / Instruction manual
page
Technical data - Operating conditions
Max. load with rod version
All ratings for 40°C (104°F)
Operating conditions
Ambient temp. (housing)
-40°C .. +70°C (-40 .. +158°F) Standard housing. Plastics housing without Ex approvals
-20°C .. +70°C (-4 .. +158°F) Plastics housing with Ex approvals
-40°C .. +60°C (-40 .. +140°F) de- and d-housing
Process temperature
RF 3100/ 3200:
-40°C .. +240°C (-40 .. +464°F)
RF 3300:
-40°C .. +500°C (-40 .. +932°F), versions with Ex-approvals: +445°C (+833°F)
.
For versions with Ex-approvals: see remarks on page 42.
Ventilation
Ventilation is not required
Max. range/ max
sensitivity
3 .. 100 pF/ 0.5 pF
3 .. 400 pF/ 2 pF
Spark protection
Robust build in protection against static discharge of the bulk material.
Features of bulk material
Min. DK depending on selected probe length L1 and probe diameter.
See tables on page 25 and 32.
Max. mechanical load
RF 3100 Rod version:
A: 125 Nm
B: 20 Nm
Rope version:
4 kN tensile load
RF 3200 Rod version:
A: 525 Nm
B: 90 Nm
Rope version:
40 kN tensile load
RF 3300 Rod version:
A: 525 Nm
B: 20 Nm
Rope version:
10 kN tensile load
Process pressure
The max. process pressure may be reduced with use of flanges. Observe flange standards for
pressure rating and pressure derating with higher temperature.
For versions with Ex-approvals: Further see remarks on page 41.
RFnivo
®
1
2
3
4
5
6
7
8
9
10
11
12
RF 3000 f
gi241014
11